82
Spyder3 GigE Vision SG-14 Monochrome Cameras User’s Manual
03-032-20123-01
Teledyne DALSA
Timestamp Counter
Counter Select
Tim estam p Cou nter (d efau lt), General Pu rp ose Cou nter .
Granularity
Ind icates the valu e of each tim estam p u nit of the tim estam p cou nter . Available valu es are:480
nanosecond s, 1 m icrosecond , 100 m icrosecond s, 10 m illisecond s.
Set Mode
Ind icates how the timestam p mod ule hand les the ―set event‖. Possible values are:
Disabled
On Ap p ly-The sp ecified valu e is set w hen the u ser clicks the Ap p ly bu tton.
Rising ed ge inp u t signal-When the signal on the ―set event‖ inp u t rises, the tim estam p m od u le ap p lies
the sp ecified valu e.
Set Input
Ind icates w hich label from the GPIO LUT that is associated with the ―set event‖ input of the timestamp
m od u le. Make su re you select an inp u t label that is not being u sed for its d efau lt behavior. The p ossible
valu es are:
0: Q3
1: Q7
2: Q8