Piranha ES-Sx User Manual
03-032-20162-00
Teledyne DALSA
42
Camera Frequency Measurement
Purpose:
Returns the frequency for the requested control signal
Syntax:
gsf i
Syntax Elements:
i
Control signal to measure:
1
: CC1 (EXSYNC)
3
: CC3 (Forward)
Example:
gsf 1
Returning Camera Settings
Returning All Camera Settings with the Camera
Parameter Screen
The camera parameter (GCP) screen returns all of the camera’s current settings.
To read all current camera settings, use the command:
Syntax:
gcp
Returning Camera Settings with Get Commands
You can also return individual camera settings by inserting a “
get”
in front of the
command that you want to query. If the command has a tap or pixel number parameter,
you must also insert the tap number or pixel number that you want to query. Refer to the
later in this manual for a list of available commands. To view a help
screen listing the following get commands, use the command
gh
.