Piranha ES-Sx User Manual
03-032-20162-00
Teledyne DALSA
14
!
WARNING: When setting up the camera’s power supplies follow these guidelines:
•
Apply the appropriate, reliable voltages
•
Protect the camera with a
slow-blow fuse
between power supply and camera (2x
nominal current).
•
Do not use the shield on a multi-conductor cable for ground.
•
Keep leads as short as possible to reduce voltage drop.
•
Use high-quality
linear
supplies to minimize noise.
•
Use an isolated type power supply to prevent LVDS common mode range violation.
•
A stable supply of power must be maintained during code upgrades. Camera will fail
if power is lost or unstable while updating code. The user can not recover from this
failure and the camera will have to be returned to Teledyne DALSA for repair.
Note: Camera performance specifications are not guaranteed if your power supply does not meet
these requirements.
Data Connectors
HSLink Pinout
SFF_8470 (or CX4) with thumbscrews
Signal
Camera
Frame Grabber
Input
Frame Grabber Signal
DataTx 2+
S16
S1
DataRx 2+
DataTx 2-
S15
S2
DataRx 2-
DataTx 1+
S14
S3
DataRx 1+
DataTx 1-
S13
S4
DataRx 1-
DataTx 0+
S12
S5
DataRx 0+
DataTx 0-
S11
S6
DataRx 0-
Cmd_T+
S10
S7
Cmd R+
Cmd_T-
S9
S8
Cmd R-
Cmd_R-
S8
S9
Cmd_T-
Cmd_R+
S7
S10
Cmd_T+
DataTx 5-
S6
S11
DataRx 5-
DataTx 5+
S5
S12
DataRx 5+
DataTx 4-
S4
S13
DataRx 4-
DataTx 4+
S3
S14
DataRx 4+
DataTx 3-
S2
S15
DataRx 3-
DataTx 3+
S1
S16
DataRx 3+
Signal
Ground
G1- G9
G1- G9
Signal Ground
Signal
Ground
H1-H2
H1-H2
Signal Ground
Input Signals
The camera accepts control inputs through the HSLink connector.