Piranha ES-Sx User Manual
Teledyne DALSA
03-032-20162-00
55
Mnemonic
Syntax Parameters Description
set exposure mode
sem
m
Set the exposure mode:
3 =
External SYNC, maximum
exposure time
7 =
Internal programmable SYNC,
maximum exposure time. Factory
setting.
set fpn coeff
sfc
x i
Set the FPN coefficient.
x
=pixel number within the range
1
to
12000
.
i
= FPN value within the range
0
to
8191
(12-bit LSB).
Refer to
page 31 for details.
set gain
sg
tf
0-30 : -20 to +20
set prnu coeff
spc
x i
Set the PRNU coefficient.
x
=pixel number within the range
1
to
12000
.
i
= PRNU value within the range
0
to
65535
set subtract background
ssb
i
Subtract the input value from the
output signal.
i
= Subtracted value in a range from
0
to
4096
set sync frequency
ssf
i
Set the frame rate to a value from:
TDI
ES-S0:
1 to 90,822
Area
ES-S0:
1 to 320
Value rounded up/down as required.
Refer to
on page 26
for details.
set system gain
ssg
i
Set the digital gain.
i
= Digital gain in a range from
0
to
61438
. The digital video values are
multiplied by this number. Refer to
on page 35 for
details.
set set number
ssn
i
0 - 4
set video mode
svm
i
Switch between normal video mode
and test patterns:
0
: Normal video mode
1
: Test pattern
2
: Test pattern
3
: Test pattern
4
: Test pattern