Piranha ES-Sx User Manual
Teledyne DALSA
03-032-20162-00
25
Exposure Modes in Detail
Frame rate is set by the period of the external trigger pulses. EXSYNC pulses faster than
the read out time are ignored. The falling edge of EXSYNC marks the start of readout.
Note: In TDI mode the frame period equals the line period.
Figure 4: Mode 3 Timing
Mode 7: Internal Frame Rate, Maximum Exposure Time
In this mode, the frame rate is set internally using the
ssf
command with a maximum
exposure time.
Note: In TDI mode the frame period equals the line period.
Figure 5: Mode 7 Camera Timing