Teledyne DALSA designed and pioneered the HSLink as a comprehensive camera-frame
grabber communication standard targeted at machine vision industry use. The HSLink
12k and frame grabber product are based on the fundamental capabilities of this new
interface.
We are working with industry partners to improve and to broaden the interface’s appeal
for the machine vision industry and as a result expect that the original specification will
change and be improved. Our products delivered during this draft specification phase
will be field upgradeable so that customers can gain the benefit from an industry
approved interface. The table below summarizes the major functions supported with the
alpha product.
HSLINK Function
Alpha
(Q4 09)
Comment
Cable Disconnect
Recovery
No
Alpha cameras will only properly lock to frame
grabber when the camera is turned on before or
after starting the data acquisition program. Turn
off the camera when exiting a program that uses
the Frame grabber.
Data Forwarding
Yes
Customer must identify the Master/Slave Frame
grabber during the system configuration step.
There is no Master/Slave communication channel
support.
Communication Between
FG
No
This is the GMII command channel and will
enable auto enumeration of slaves and data
resend requests from the slaves.
Video Data Resend
No
Master/Slave command channel used for error
communication from slave is not available at this
time. Can be field upgraded.
LED functions
No
GeniCam
No
Use the ASCII serial command set for the Alphas.
Trigger/ Direction
Control
Yes
Area/Line Scan Mode
Yes
12 bit mode
No
Data will be packed on the Link. This will exceed
the PCIx 8 Gen 1 bandwidth.
Missed Trigger Flag
No
DATA CRC Error Flag
Yes
CRC error counters available
Header Error Flag
Yes
Header error counter available
8b/10B Error counter
Yes
Enables BER calculation
Test Patterns
Yes
Good for system debug
Data Lost Flag
No
Indicates missing rows of information
Camera Data buffer
overflow
No
Idle Lock Lost
No
Far end Reset
No
Cmd Packet Failure
No