![background image](http://html1.mh-extra.com/html/dallmeier/dis-1-s/dis-1-s_operating-manual-installation-and-configuration_3324103052.webp)
52
DIS-1/S and DIS-1/L
Dallmeier electronic GmbH & Co.KG
8.2.2
Contact
If you have selected the Contact mode, recording will only start in response
to a corresponding contact. Recording will then stop again when the contact
is canceled.
The contact you wish to use here can be set in the Contact tab.
Settings
!
Open the tab Contact.
!
In the Rec. contact (A) box, select the
desired contact on Contact IN.
Check the contact assignment of Contact IN
in the appendix
If the contact used is an „Opener“ (idle state =
contact closed), please mark the checkbox Invert
signal (B).
8.2.3
Contact with Timer
When Contact with timer is set, recording is triggered in the same way
as under the Contact mode. However, recording will stop after the expiry
of a pre-set time - Duration (sec.) box.
Settings
!
Open the tab Contact with timer.
!
In the Start contact (C) box, select the desired
contact on Contact IN.
Check the contact assignment of Contact IN
in the appendix.
If the contact used is an „Opener“ (idle state =
contact closed), please mark the checkbox Invert
signal (E).
!
In the Duration (sec.) box, set the recording
duration in seconds (D).
A
B
C
D
E
Diagram. 8-12