2
. Terms and Symbols17
jack.
We call this
Monopolar Outlet 1.
36. Mono-polar RF power Outlet 2
For hand switchable Mono-polar accessories.
No hand switchable Mono-polar accessories or
Mono-polar coagulating Forceps may be used
by connecting to long distance terminals in one
jack.
We call this
Monopolar Outlet 1.
37. Return Electrode Inlet
This jack accepts a standard return electrode
plug.
38. Sound Volume Controller
39. Bi-polar Foot Switch Inlet
Is a 3-pin threaded connector designed to
accept plugs attached to any two treadle mono-
polar foot switch available from DAIWHA.
40. Mono-polar Foot Switch Inlet
Is a 3-pin threaded connector designed to
accept plugs attached to any two treadle
mono-polar foot switch available from
DAIWHA.
41. Main Inlet with Main Fuse case
Supplies ac main power to the unit. It only
should be connected to a source of power
corresponding to that listed on the Patcher
attached right by. A detachable power cord with
a standard 3-prong are supplied with unit. The
fuses in main fuse box provide Dual-pole power
line overload protection.
42. Equipotential Grounding
Is Chassis ground connection for additional
protection against low frequency risk current.
43. Assist Resistance Indicator
This red LED bar graph is a visual indicator of
patient resistance measured between the
contacts of the return electrode. The number of
red bars illuminated increases with decreasing
resistance and may be used as an aid in
detecting high risk patients. The Assist
Resistance Indicator will light 3 to 8 bars when
the patient's return electrode resistance is within
range.
44. Single Pad Mode Indicator
Illuminates when the Single pad mode is
selected.
45. Dual Pad Mode Indicator
Illuminates when the Dual pad mode is
selected.
46. Main Power Switch
Turns unit on and off.
47. Output Path Selector
This Switch change the path of RF Output
activated by Mono-polar Foot Switch to
Monopolar Outlet 1 or 2
Summary of Contents for Meditom DT-400S
Page 29: ...5 Connecting Accessories with the unit29 5 3 Bipolar Forceps 5 4 Foot switches ...
Page 40: ...9 Load Regulation Vpeak Graphs40 9 1 2Open Circuit Peak Voltage ...
Page 41: ...9 Load Regulation Vpeak Graphs41 9 2 Blend1 Cutting Mode 9 2 1Load Regulation DT 400S DT 300S ...
Page 42: ...9 Load Regulation Vpeak Graphs42 9 2 2Open Circuit Peak Voltage ...
Page 43: ...9 Load Regulation Vpeak Graphs43 9 3 Blend2 Cutting Mode 9 3 1Load Regulation DT 400S DT 300S ...
Page 44: ...9 Load Regulation Vpeak Graphs44 9 3 2Open Circuit Peak Voltage ...
Page 45: ...9 Load Regulation Vpeak Graphs45 9 4 Blend3 Cutting Mode 9 4 1Load Regulation DT 400S DT 300S ...
Page 46: ...9 Load Regulation Vpeak Graphs46 9 4 2Open Circuit Peak Voltage ...
Page 48: ...9 Load Regulation Vpeak Graphs48 9 5 2Open Circuit Peak Voltage ...