1
. Precautions11
1.5 Checklist before use
1) Check and clear away flammable gas or solvent.
2) Check the cable connection on the back panel of the unit.
3) Check that all accessories that have direct contact with patients are sterilized.
4) Check all accessories in order to prevent damage or malfunction of the unit.
5) Check the DRM function in order to prevent patients from burning due to wrong measurement
of contact size that happens at the time of unit troubles.
6) Check contact status between patient plate and patient.
1.6 Precautions during use
1) Check appropriateness when you change the existing settings, considering operation type and
biological tissue. Please refer to ‘7. Output Setting Guide,’ if necessary.
2) Make sure that patients do not touch grounded metals. It may cause partial burn.
3) Do not give long output to tissue areas or do not give approval high output beyond the need.
Manipulate output when electrode is always contacted with tissue to prevent tissue burn.
4) If the patient complains about electric shock, stop using the unit immediately and have it examined
thoroughly.
5) Frequently check contact status between patient plate and patient, especially when using a single
pad or using reusable plate as return electrode.
6) The sound volume should be at least the medium of level to prevent sound-recognition-fail caused
dangers.
1.7 Guidelines after use
1) Please sterilize reusable accessories before you keep in store.
2) Scrap disposable accessories in the prescribed regulations (according to the law). Scrap
disposable accessories in the way that there is no risk of contamination due to the used consumable
accessories.
Summary of Contents for Meditom DT-400S
Page 29: ...5 Connecting Accessories with the unit29 5 3 Bipolar Forceps 5 4 Foot switches ...
Page 40: ...9 Load Regulation Vpeak Graphs40 9 1 2Open Circuit Peak Voltage ...
Page 41: ...9 Load Regulation Vpeak Graphs41 9 2 Blend1 Cutting Mode 9 2 1Load Regulation DT 400S DT 300S ...
Page 42: ...9 Load Regulation Vpeak Graphs42 9 2 2Open Circuit Peak Voltage ...
Page 43: ...9 Load Regulation Vpeak Graphs43 9 3 Blend2 Cutting Mode 9 3 1Load Regulation DT 400S DT 300S ...
Page 44: ...9 Load Regulation Vpeak Graphs44 9 3 2Open Circuit Peak Voltage ...
Page 45: ...9 Load Regulation Vpeak Graphs45 9 4 Blend3 Cutting Mode 9 4 1Load Regulation DT 400S DT 300S ...
Page 46: ...9 Load Regulation Vpeak Graphs46 9 4 2Open Circuit Peak Voltage ...
Page 48: ...9 Load Regulation Vpeak Graphs48 9 5 2Open Circuit Peak Voltage ...