3 User safety instructions

Installation and operation manual

6

FXMQ-A

VRV system air conditioner

3P701545-1 – 2022.07

concerning use of the appliance in a
safe way and understand the hazards
involved.

Children SHALL NOT play with the
appliance.

Cleaning and user maintenance
SHALL NOT be made by children
without supervision.

WARNING

To prevent electrical shocks or fire:

▪ Do NOT rinse the unit.

▪ Do NOT operate the unit with wet

hands.

▪ Do NOT place any objects containing

water on the unit.

CAUTION

▪ Do NOT place any objects or

equipment on top of the unit.

▪ Do NOT sit, climb or stand on the

unit.

▪ Units are marked with the following symbol:

This  means  that  electrical  and  electronic  products  may  NOT  be
mixed  with  unsorted  household  waste.  Do  NOT  try  to  dismantle
the  system  yourself:  dismantling  the  system,  treatment  of  the
refrigerant,  of  oil  and  of  other  parts  MUST  be  done  by  an
authorised installer and MUST comply with applicable legislation.

Units MUST be treated at a specialised treatment facility for reuse,
recycling  and  recovery.  By  ensuring  this  product  is  disposed  of
correctly, you will help to prevent potential negative consequences
for  the  environment  and  human  health.  For  more  information,
contact your installer or local authority.

▪ Batteries are marked with the following symbol:

This  means  that  the  batteries  may  NOT  be  mixed  with  unsorted
household  waste.  If  a  chemical  symbol  is  printed  beneath  the
symbol,  this  chemical  symbol  means  that  the  battery  contains  a
heavy metal above a certain concentration.

Possible chemical symbols are: Pb: lead (>0.004%).

Waste  batteries  MUST  be  treated  at  a  specialised  treatment
facility  for  reuse.  By  ensuring  waste  batteries  are  disposed  of
correctly, you will help to prevent potential negative consequences
for the environment and human health.

3.2

Instructions for safe operation

WARNING

▪ Do NOT modify, disassemble,

remove, reinstall or repair the unit
yourself as incorrect dismantling or
installation may cause an electrical
shock or fire. Contact your dealer.

▪ In case of accidental refrigerant

leaks, make sure there are no naked
flames. The refrigerant itself is
entirely safe, non-toxic and non-
combustible, but it will generate toxic
gas when it accidentally leaks into a
room where combustion air from fan
heaters, gas cookers, etc. is present.
ALWAYS have qualified service
personnel confirm that the point of
leakage has been repaired or
corrected before resuming operation.

CAUTION

▪ NEVER touch the internal parts of the

controller.

▪ Do NOT remove the front panel.

Some parts inside are dangerous to
touch and appliance problems may
happen. For checking and adjusting
the internal parts, contact your
dealer.

WARNING

This unit contains electrical and hot
parts.

WARNING

Before operating the unit, be sure the
installation has been carried out
correctly by an installer.

CAUTION

It is unhealthy to expose your body to
the air flow for a long time.

CAUTION

To avoid oxygen deficiency, ventilate
the room sufficiently if equipment with
burner is used together with the
system.

Summary of Contents for VRV system FXMQ200AXVMB

Page 1: ...Installation and operation manual VRV system air conditioner English Installation and operation manual VRV system air conditioner FXMQ200AXVMB FXMQ250AXVMB...

Page 2: ...laikantis m s instrukcij atbilst d m direkt v m vai regul m ja vien ie izstr d jumi tiek lietoti saska ar m su instrukcij m s v zhode s nasleduj cou imi smernicou ami alebo predpisom mi za predpokladu...

Page 3: ...accordance with our instructions as amended S I 2008 1597 Supply of Machinery Safety Regulations 2008 S I 2016 1091 Electromagnetic Compatibility Regulations 2016 following the provisions of BS EN 60...

Page 4: ...Configuration 17 16 1 Field setting 17 17 Technical data 20 17 1 Wiring diagram 20 17 1 1 Unified wiring diagram legend 20 1 About the documentation 1 1 About this document INFORMATION Make sure that...

Page 5: ...iring All components procured on site and all electrical construction MUST comply with the applicable legislation WARNING If the power supply has a missing or wrong N phase equipment might break down...

Page 6: ...the symbol this chemical symbol means that the battery contains a heavy metal above a certain concentration Possible chemical symbols are Pb lead 0 004 Waste batteries MUST be treated at a specialise...

Page 7: ...unit may fall and result in injury CAUTION Before accessing terminal devices make sure to interrupt all power supply DANGER RISK OF ELECTROCUTION To clean the air conditioner or air filter be sure to...

Page 8: ...for future system extensions is available in technical engineering data and should be consulted Contact your installer to receive more information and professional advice 4 1 System layout INFORMATIO...

Page 9: ...he indoor unit fan will stop operation and the following icon will appear on the home screen 6 3 To operate the system INFORMATION For setting of the operation mode or other settings see the reference...

Page 10: ...unit is indicated both in weight and CO2 equivalent Formula to calculate the quantity in CO2 equivalent tonnes GWP value of the refrigerant total refrigerant charge in kg 1000 Contact your installer f...

Page 11: ...tion site 12 1 1 Installation site requirements of the indoor unit INFORMATION The sound pressure level is less than 70 dBA INFORMATION Equipment meets the requirement for commercial and light industr...

Page 12: ...using a nut and washer from the upper and lower sides of the hanger bracket e 1526 e 1028 a b b d c a Nut field supply b Washer accessories c Hanger bracket d Double nut field supply e Suspension bolt...

Page 13: ...s 7 Wind aluminium tape around the flanges and duct connections Make sure there are no air leaks at any other connection 8 Insulate the ducts to prevent condensation from forming Use glass wool or pol...

Page 14: ...he electrical wiring Remove the service cover Disconnect the power supply Disconnect the user interface Reattach the service cover When installation of the system is already completed 1 Start cooling...

Page 15: ...er accessory d Attached piping e Sealing on the attached piping f Indoor unit NOTICE Join the attached piping accessory and the field refrigerant piping field supply by brazing before fixing the attac...

Page 16: ...F2 match with the symbols on the outdoor unit Bundle the transmission cable with the user interface cable and fix them with a tie wrap on the wiring fixture 4 Power supply cable Route the cable throug...

Page 17: ...supply panel The voltage MUST correspond to the voltage on the nameplate of the unit Earth wiring Be sure that the earth wires have been connected properly and that the earth terminals are tightened...

Page 18: ...11 21 7 01 Completion of automatic airflow adjustment 02 Start of automatic airflow adjustment 03 To set external static pressure by the user interface Check the indoor unit setting the value number m...

Page 19: ...fference between cooling setpoint and heating setpoint in automatic mode availability depends on the system type Differential is cooling setpoint minus heating setpoint If you want to set Then 1 Examp...

Page 20: ...connector D V D Diode DB Diode bridge DS DIP switch E H Heater FU F U for characteristics refer to PCB inside your unit Fuse FG Connector frame ground H Harness H P LED V L Pilot lamp light emitting...

Page 21: ...n and operation manual 21 FXMQ A VRV system air conditioner 3P701545 1 2022 07 Symbol Meaning X M Terminal strip block Y E Electronic expansion valve coil Y R Y S Reversing solenoid valve coil Z C Fer...

Page 22: ......

Page 23: ......

Page 24: ...3P701545 1 2022 07 Copyright 2022 Daikin Verantwortung f r Energie und Umwelt...

Reviews: