4 About the system

Installation and operation manual

8

FXMQ-A

VRV system air conditioner

3P701545-1 – 2022.07

Troubleshooting (see 

"8 Troubleshooting"

 [

4

 10])

WARNING

Stop operation and shut OFF the
power if anything unusual occurs
(burning smells etc.).

Leaving the unit running under such
circumstances may cause breakage,
electrical shock or fire. Contact your
dealer.

4

About the system

WARNING

▪ Do  NOT  modify,  disassemble,  remove,  reinstall  or

repair  the  unit  yourself  as  incorrect  dismantling  or
installation  may  cause  an  electrical  shock  or  fire.
Contact your dealer.

▪ In case of accidental refrigerant leaks, make sure there

are  no  naked  flames.  The  refrigerant  itself  is  entirely
safe,  non-toxic  and  non-combustible,  but  it  will
generate  toxic  gas  when  it  accidentally  leaks  into  a
room  where  combustion  air  from  fan  heaters,  gas
cookers,  etc.  is  present.  ALWAYS  have  qualified
service personnel confirm that the point of leakage has
been repaired or corrected before resuming operation.

NOTICE

Do  NOT  use  the  system  for  other  purposes.  In  order  to
avoid  any  quality  deterioration,  do  NOT  use  the  unit  for
cooling  precision  instruments,  food,  plants,  animals,  or
works of art.

NOTICE

For future modifications or expansions of your system:

A  full  overview  of  allowable  combinations  (for  future
system  extensions)  is  available  in  technical  engineering
data  and  should  be  consulted.  Contact  your  installer  to
receive more information and professional advice.

4.1

System layout

INFORMATION

The  following  figure  is  an  example  and  may  NOT
completely match your system layout

+

-

+

-

a

b

c

d

d

c

a

Outdoor unit

b

Multi BS unit

c

Indoor unit

d

Remote controller (user interface)

5

User interface

CAUTION

▪ NEVER touch the internal parts of the controller.

▪ Do NOT remove the front panel. Some parts inside are

dangerous  to  touch  and  appliance  problems  may
happen.  For  checking  and  adjusting  the  internal  parts,
contact your dealer.

NOTICE

Do  NOT  wipe  the  controller  operation  panel  with  benzine,
thinner,  chemical  dust  cloth,  etc.  The  panel  may  get
discoloured  or  the  coating  peeled  off.  If  it  is  heavily  dirty,
soak  a  cloth  in  water-diluted  neutral  detergent,  squeeze  it
well  and  wipe  the  panel  clean.  Wipe  it  with  another  dry
cloth.

NOTICE

NEVER press the button of the user interface with a hard,
pointed object. The user interface may be damaged.

NOTICE

NEVER pull or twist the electric wire of the user interface. It
may cause the unit to malfunction.

This operation manual offers a non-exhaustive overview of the main
functions of the system.

For  more  information  about  the  user  interface,  see  the  operation
manual of the installed user interface.

6

Operation

6.1

Operation range

INFORMATION

For  the  operation  limits  see  the  technical  data  of  the
connected outdoor unit.

Summary of Contents for VRV system FXMQ200AXVMB

Page 1: ...Installation and operation manual VRV system air conditioner English Installation and operation manual VRV system air conditioner FXMQ200AXVMB FXMQ250AXVMB...

Page 2: ...laikantis m s instrukcij atbilst d m direkt v m vai regul m ja vien ie izstr d jumi tiek lietoti saska ar m su instrukcij m s v zhode s nasleduj cou imi smernicou ami alebo predpisom mi za predpokladu...

Page 3: ...accordance with our instructions as amended S I 2008 1597 Supply of Machinery Safety Regulations 2008 S I 2016 1091 Electromagnetic Compatibility Regulations 2016 following the provisions of BS EN 60...

Page 4: ...Configuration 17 16 1 Field setting 17 17 Technical data 20 17 1 Wiring diagram 20 17 1 1 Unified wiring diagram legend 20 1 About the documentation 1 1 About this document INFORMATION Make sure that...

Page 5: ...iring All components procured on site and all electrical construction MUST comply with the applicable legislation WARNING If the power supply has a missing or wrong N phase equipment might break down...

Page 6: ...the symbol this chemical symbol means that the battery contains a heavy metal above a certain concentration Possible chemical symbols are Pb lead 0 004 Waste batteries MUST be treated at a specialise...

Page 7: ...unit may fall and result in injury CAUTION Before accessing terminal devices make sure to interrupt all power supply DANGER RISK OF ELECTROCUTION To clean the air conditioner or air filter be sure to...

Page 8: ...for future system extensions is available in technical engineering data and should be consulted Contact your installer to receive more information and professional advice 4 1 System layout INFORMATIO...

Page 9: ...he indoor unit fan will stop operation and the following icon will appear on the home screen 6 3 To operate the system INFORMATION For setting of the operation mode or other settings see the reference...

Page 10: ...unit is indicated both in weight and CO2 equivalent Formula to calculate the quantity in CO2 equivalent tonnes GWP value of the refrigerant total refrigerant charge in kg 1000 Contact your installer f...

Page 11: ...tion site 12 1 1 Installation site requirements of the indoor unit INFORMATION The sound pressure level is less than 70 dBA INFORMATION Equipment meets the requirement for commercial and light industr...

Page 12: ...using a nut and washer from the upper and lower sides of the hanger bracket e 1526 e 1028 a b b d c a Nut field supply b Washer accessories c Hanger bracket d Double nut field supply e Suspension bolt...

Page 13: ...s 7 Wind aluminium tape around the flanges and duct connections Make sure there are no air leaks at any other connection 8 Insulate the ducts to prevent condensation from forming Use glass wool or pol...

Page 14: ...he electrical wiring Remove the service cover Disconnect the power supply Disconnect the user interface Reattach the service cover When installation of the system is already completed 1 Start cooling...

Page 15: ...er accessory d Attached piping e Sealing on the attached piping f Indoor unit NOTICE Join the attached piping accessory and the field refrigerant piping field supply by brazing before fixing the attac...

Page 16: ...F2 match with the symbols on the outdoor unit Bundle the transmission cable with the user interface cable and fix them with a tie wrap on the wiring fixture 4 Power supply cable Route the cable throug...

Page 17: ...supply panel The voltage MUST correspond to the voltage on the nameplate of the unit Earth wiring Be sure that the earth wires have been connected properly and that the earth terminals are tightened...

Page 18: ...11 21 7 01 Completion of automatic airflow adjustment 02 Start of automatic airflow adjustment 03 To set external static pressure by the user interface Check the indoor unit setting the value number m...

Page 19: ...fference between cooling setpoint and heating setpoint in automatic mode availability depends on the system type Differential is cooling setpoint minus heating setpoint If you want to set Then 1 Examp...

Page 20: ...connector D V D Diode DB Diode bridge DS DIP switch E H Heater FU F U for characteristics refer to PCB inside your unit Fuse FG Connector frame ground H Harness H P LED V L Pilot lamp light emitting...

Page 21: ...n and operation manual 21 FXMQ A VRV system air conditioner 3P701545 1 2022 07 Symbol Meaning X M Terminal strip block Y E Electronic expansion valve coil Y R Y S Reversing solenoid valve coil Z C Fer...

Page 22: ......

Page 23: ......

Page 24: ...3P701545 1 2022 07 Copyright 2022 Daikin Verantwortung f r Energie und Umwelt...

Reviews: