3 User safety instructions

Installation and operation manual

7

FXMQ-A
VRV system air conditioner
3P701545-1 – 2022.07

CAUTION

Do NOT operate the system when
using a room fumigation-type
insecticide. Chemicals could collect in
the unit, and endanger the health of
people who are hypersensitive to
chemicals.

CAUTION

NEVER expose little children, plants or
animals directly to the airflow.

WARNING

Do NOT place a flammable spray
bottle near the air conditioner and do
NOT use sprays near the unit. Doing
so may result in a fire.

Maintenance and service (see 

"7 Maintenance and

service"

 [

4

 9])

CAUTION: Pay attention to the fan!

It is dangerous to inspect the unit while
the fan is running.

Make sure to turn OFF the main switch
before executing any maintenance
task.

CAUTION

Do NOT insert fingers, rods or other
objects into the air inlet or outlet. When
the fan is rotating at high speed, it will
cause injury.

WARNING

NEVER replace a fuse with a fuse of a
wrong ampere ratings or other wires
when a fuse blows out. Use of wire or
copper wire may cause the unit to
break down or cause a fire.

CAUTION

After a long use, check the unit stand
and fitting for damage. If damaged, the
unit may fall and result in injury.

CAUTION

Before accessing terminal devices,
make sure to interrupt all power supply.

DANGER: RISK OF
ELECTROCUTION

To clean the air conditioner or air filter,
be sure to stop operation and turn all
power supplies OFF. Otherwise, an
electrical shock and injury may result.

WARNING

Be careful with ladders when working
in high places.

DANGER: RISK OF
ELECTROCUTION

Disconnect the power supply for more
than 10 minutes, and measure the
voltage at the terminals of main circuit
capacitors or electrical components
before servicing. The voltage MUST be
less than 50 V DC before you can
touch electrical components. For the
location of the terminals, see the
warning label for persons performing
service and maintenance.

CAUTION

Turn off the unit before cleaning the air
outlet.

WARNING

Do NOT let the indoor unit get wet.

Possible consequence: 

Electrical

shock or fire.

About the refrigerant (see 

"7.3 About the refrigerant"

 [

4

 10])

WARNING

▪ The refrigerant in the system is safe

and normally does NOT leak. If the
refrigerant leaks in the room, contact
with a fire of a burner, a heater or a
cooker may result in a harmful gas.

▪ Turn OFF any combustible heating

devices, ventilate the room and
contact the dealer where you
purchased the unit.

▪ Do NOT use the system until a

service person confirms that the
portion where the refrigerant leaks is
repaired.

Summary of Contents for VRV system FXMQ200AXVMB

Page 1: ...Installation and operation manual VRV system air conditioner English Installation and operation manual VRV system air conditioner FXMQ200AXVMB FXMQ250AXVMB...

Page 2: ...laikantis m s instrukcij atbilst d m direkt v m vai regul m ja vien ie izstr d jumi tiek lietoti saska ar m su instrukcij m s v zhode s nasleduj cou imi smernicou ami alebo predpisom mi za predpokladu...

Page 3: ...accordance with our instructions as amended S I 2008 1597 Supply of Machinery Safety Regulations 2008 S I 2016 1091 Electromagnetic Compatibility Regulations 2016 following the provisions of BS EN 60...

Page 4: ...Configuration 17 16 1 Field setting 17 17 Technical data 20 17 1 Wiring diagram 20 17 1 1 Unified wiring diagram legend 20 1 About the documentation 1 1 About this document INFORMATION Make sure that...

Page 5: ...iring All components procured on site and all electrical construction MUST comply with the applicable legislation WARNING If the power supply has a missing or wrong N phase equipment might break down...

Page 6: ...the symbol this chemical symbol means that the battery contains a heavy metal above a certain concentration Possible chemical symbols are Pb lead 0 004 Waste batteries MUST be treated at a specialise...

Page 7: ...unit may fall and result in injury CAUTION Before accessing terminal devices make sure to interrupt all power supply DANGER RISK OF ELECTROCUTION To clean the air conditioner or air filter be sure to...

Page 8: ...for future system extensions is available in technical engineering data and should be consulted Contact your installer to receive more information and professional advice 4 1 System layout INFORMATIO...

Page 9: ...he indoor unit fan will stop operation and the following icon will appear on the home screen 6 3 To operate the system INFORMATION For setting of the operation mode or other settings see the reference...

Page 10: ...unit is indicated both in weight and CO2 equivalent Formula to calculate the quantity in CO2 equivalent tonnes GWP value of the refrigerant total refrigerant charge in kg 1000 Contact your installer f...

Page 11: ...tion site 12 1 1 Installation site requirements of the indoor unit INFORMATION The sound pressure level is less than 70 dBA INFORMATION Equipment meets the requirement for commercial and light industr...

Page 12: ...using a nut and washer from the upper and lower sides of the hanger bracket e 1526 e 1028 a b b d c a Nut field supply b Washer accessories c Hanger bracket d Double nut field supply e Suspension bolt...

Page 13: ...s 7 Wind aluminium tape around the flanges and duct connections Make sure there are no air leaks at any other connection 8 Insulate the ducts to prevent condensation from forming Use glass wool or pol...

Page 14: ...he electrical wiring Remove the service cover Disconnect the power supply Disconnect the user interface Reattach the service cover When installation of the system is already completed 1 Start cooling...

Page 15: ...er accessory d Attached piping e Sealing on the attached piping f Indoor unit NOTICE Join the attached piping accessory and the field refrigerant piping field supply by brazing before fixing the attac...

Page 16: ...F2 match with the symbols on the outdoor unit Bundle the transmission cable with the user interface cable and fix them with a tie wrap on the wiring fixture 4 Power supply cable Route the cable throug...

Page 17: ...supply panel The voltage MUST correspond to the voltage on the nameplate of the unit Earth wiring Be sure that the earth wires have been connected properly and that the earth terminals are tightened...

Page 18: ...11 21 7 01 Completion of automatic airflow adjustment 02 Start of automatic airflow adjustment 03 To set external static pressure by the user interface Check the indoor unit setting the value number m...

Page 19: ...fference between cooling setpoint and heating setpoint in automatic mode availability depends on the system type Differential is cooling setpoint minus heating setpoint If you want to set Then 1 Examp...

Page 20: ...connector D V D Diode DB Diode bridge DS DIP switch E H Heater FU F U for characteristics refer to PCB inside your unit Fuse FG Connector frame ground H Harness H P LED V L Pilot lamp light emitting...

Page 21: ...n and operation manual 21 FXMQ A VRV system air conditioner 3P701545 1 2022 07 Symbol Meaning X M Terminal strip block Y E Electronic expansion valve coil Y R Y S Reversing solenoid valve coil Z C Fer...

Page 22: ......

Page 23: ......

Page 24: ...3P701545 1 2022 07 Copyright 2022 Daikin Verantwortung f r Energie und Umwelt...

Reviews: