PIM-00004
△
1
[Operation Manual]
50/61
DAIKIN INDUSTRIES, LTD.
Oil filling port (air breather) maintenance procedure
1. Removing procedure
The cap can be easily removed by turning it counterclockwise by
hand.
2. Cleaning procedure
Blow air onto the filter to blow off dust accumulated on/adhering to
the filter.
Remove dust from inside of the strainer cylinder.
<Oil filling port (Air breather)>
3. Mounting direction
Mount the cap by turning it clockwise by hand until it stops.
WARNING
During air blow, wear protective goggles to prevent accumulated substances or dust from touching your
eyes.
Suction strainer maintenance procedure
1. Removing procedure
[1] After draining hydraulic oil completely, remove
the nuts (M8: 12 pieces; Tightening torque: 9 to
10 N
m) from the cleaning door cover, and
remove the cover from the cleaning door.
* When the Super Unit uses the 160 L tank,
there are 14 nuts for the cleaning door.
[2] You can see the suction strainer. Loosen the
strainer, and remove it.
(Hexagon nut, Width across flats: 41 mm)
2. Cleaning procedure
Blow air onto the filter to blow off dust accumulated
on/adhering to the filter.
Remove dust from inside of the strainer cylinder.
3. Reassembling the strainer
After cleaning is completed, reassemble the suction
strainer. Follow the removing procedure in reverse.
After reassembling is completed, conduct the test run
procedure described on p. 29 to make sure that the
hydraulic unit normally operates.
WARNING
During air blow, wear protective goggles to prevent accumulated substances or dust from touching your
eyes.
Cap
Strainer
Cleaning door cover
Nut
Suction strainer
Cleaning door tightening
precaution nameplate
Safety precaution
nameplate
Unit nameplate