Pressure setting changing procedure
An example of pressure setting changing operation is shown below.
<Example> Changing pressure for P-Q selection 1 from 7.0 MPa to 6.0 MPa
When the PQ selection is not changed over, do not change the item number, but select P00 and set PQ
selection at 0.
Operating procedure
Key operation
3-digit
LED
Remarks
Power-ON
Actual pressure display
Setting mode
Keep pressing two
keys simultaneously
for at least two
seconds.
After two seconds
Parameter No. selection
or
P-Q selection 1
Set value display
Displays pressure setting
of high-pressure pump for
P-Q selection 1.
P-Q selection
Press
two times.
"PH.1", "qH.1", "PL.1",
"qL.1", "Ut.1" and "dt.1"
are alternately
displayed in this order.
Displays flow rate setting
of low-pressure pump for
P-Q selection 1.
Changing set value
or
Writing set value
Displays flow rate setting
of low-pressure pump
after writing low-pressure
pump pressure setting.
Return to actual pressure
display mode