PIM00413
13-4
Alarm
Code
Name Reason
Countermeasure
Fin thermistor cable is
disconnected
・
Replace the thermistor
E42
Radiator fin thermistor cable
break
The heat dissipation fin thermistor
is short-circuited or disconnected
Failure of the controller
・
Replace the controller
The cooling fan for controller is
stopped
・
Replace the fuse for cooling fan
・
Replace the cooling fan
・
Replace the controller
Radiator is clogged
・
Replace or clean the radiator
Rotation speed of the motor is
rising
・
Check the leakage amount in the
main unit side circuit
・
Check the setting of the high-
pressure safety valve
・
Replace the motor pump
The ambient temperature is high
・
Install it in the place where the
ambient temperature is within the
required range
・
Install in well-ventilated place
E43
Fin temperature abnormal rise
Fin temperature exceeded the
specified value over 30 seconds or
more
Failure of the controller
・
Replace the controller
Oil level is low
・
Inject the hydraulic oil
Stop valve is closed
・
Open the stop valve
E64
Drying operation error
Start the pump when the oil level is
low
It takes time to suction oil
・
Reduce the parameter value of
"P35: Dry running judgment
pressure ", "P36: Dry running
judgment time "
CPU runs away
・
Sudden abnormal(Continuous use
available)
E91
CPU runaway
The stored parameter setting value
is out of range
Program execution time error
・
Replace the control board or
controller
E93
EEPROM
data error (1)
The stored parameter setting value
is out of range
EEPROM data error
E94
EEPROM
data error (1)
The stored parameter setting value
is out of range
EEPROM data error
・
The "E94" or "E93" and the
abnormal parameter is displayed
alternately on the display panel.
Please set the setting value of the
displayed parameter number
within its range
13.1.3
Warning
The actual pressure and the following warning code is displayed alternately on the operation panel, if a warning
occurs.
The warning signal will be output in accordance with the setting values of parameters.
Please refer to
"13.1.1 Output signal of the protection function" for more information.
In warning state, the unit will continue operating. However, there is a possibility that the protection function will be
activated and an alarm will be generated, if you continue operating, ignoring the warning state.
◆
Warning causes and countermeasures
Warning
Code
Name Reason
Countermeasures
Summary of Contents for SUT06S3016-30
Page 2: ......
Page 12: ......
Page 20: ...PIM00413 3 6 3 4 Dimensions Motor Pump Type SUT00 SUT00S3016 30...
Page 21: ...PIM00413 3 7 SUT00S6007 30...
Page 22: ...PIM00413 3 8 SUT00D4016 30 SUT00D6021 30 Product type Dimension...
Page 23: ...PIM00413 3 9 Unit Type SUT06 SUT10 SUT06S3016 30...
Page 24: ...PIM00413 3 10 SUT06S6007 30...
Page 25: ...PIM00413 3 11 SUT06D4016 30 SUT06D6021 30 1 327 for SUT06D6021 30 2 188 for SUT06D6021 30 2...
Page 26: ...PIM00413 3 12 SUT10D6021 30...
Page 36: ......
Page 38: ......
Page 42: ......
Page 54: ......
Page 64: ......