PIM00413
12-4
Item Sign
Name
Operating
range
Default
setting
Description Reference
parameter to avoid the unstable state.
P30 DF_N
Single switching
rotation dead zone 0
〜
999[min-1]
Please
refer to
12-6
Table1
Set the conditions of the motor speed
when switching to single mode from
confluence.
When the confluence flow rate drops
from the parameter ”high-pressure side
flow rate setting” over this parameter, the
pump will change to single mode.
If the pump switches between confluence
and single mode frequently, please set a
large value to avoid the unstable state.
−
P31 P_SN
Pressure sensor
ratings
1
〜
35[MPa]
35
Setting the rated pressure of the pressure
sensor.
Usually it is not necessary to change the
settings.
−
P32 S_TM
Surge less start-up
time
0.01
〜
9.99[sec]
0.5
Setting the start-up time from the motor
stop to start-up.
Increasing the value can prevent the
rising surge. But the response time of
start-up will be longer.
12-16
P33 L_IN
Motor start initial
response gain
1
〜
999
10
Setting the output of the motor at the time
of start-up.
Decreasing the value can prevent the
rising surge. But the response time of
start-up will be longer.
12-16
P34 E_TM
Motor start-up
abnormality
judgment time
0.01
〜
9.99[sec]
2
Setting the judgment time of the alarm
“E31: Motor start-up abnormality”.
−
0.00
〜
2.00[MPa]
0.5
P35 DR_L
Dry running
judgment pressure 0
〜
290[PSI]
7.2
Setting the pressure conditions to
determine the alarm “E64: Dry running
abnormality”.
−
P36 DR_T
Dry running
judgment time
0.01
〜
9.99[sec]
3
Setting the time of determining the alarm
“E64: Dry running abnormality”.
−
P37 SM_R
Same pressure
confluence rate
0
〜
100[%]
80
Set the switching pressure from
confluence to single mode, by the ratio to
the parameter “low-pressure side pressure
set”. If the pressure decreases over this
setting value, pump will switch to
confluence mode.
Only when the difference between tow
parameters "low-pressure side pressure
set" and "high-pressure side pressure
setting" is 0.5 [MPa] or less, this
parameter will be enabled.
If the pump switches between confluence
and single mode frequently, please set a
small value to avoid the unstable state.
−
0.00
〜
1.00[MPa]
0.5
P38 P_DF
Pressure switch
output dead zone 0
〜
145[×10 PSI]
7.2
Setting the pressure threshold value for
determining the pressure return, after the
pressure switch being actuated.
Setting by the difference of the positive
direction for:" P01: pressure switch".
12-13
Summary of Contents for SUT06S3016-30
Page 2: ......
Page 12: ......
Page 20: ...PIM00413 3 6 3 4 Dimensions Motor Pump Type SUT00 SUT00S3016 30...
Page 21: ...PIM00413 3 7 SUT00S6007 30...
Page 22: ...PIM00413 3 8 SUT00D4016 30 SUT00D6021 30 Product type Dimension...
Page 23: ...PIM00413 3 9 Unit Type SUT06 SUT10 SUT06S3016 30...
Page 24: ...PIM00413 3 10 SUT06S6007 30...
Page 25: ...PIM00413 3 11 SUT06D4016 30 SUT06D6021 30 1 327 for SUT06D6021 30 2 188 for SUT06D6021 30 2...
Page 26: ...PIM00413 3 12 SUT10D6021 30...
Page 36: ......
Page 38: ......
Page 42: ......
Page 54: ......
Page 64: ......