PIM00413
1-3
If this unit is continuously used in the state that the safety valve is actuated, it may output an alarm due to a
temperature rise and so on.In this case, re-adjust the high pressure safety valve pressure setting according to
“13.8 High-pressure Safety Valve Adjustment Procedure” in this instruction manual.
(
7
)
If it is continuously used at the highest pressure, please follow the flowrate in the table below.
■
Continuous flow rate at the highest pressure
Product Type
Flowrate
SUT00S3016 / SUT06S3016
Less than 5.0L/min
SUT00S6007 / SUT06S6007
Less than 14.0L/min
SUT00D4016 / SUT06D4016
Less than 8.0L/min
SUT00D6021 / SUT06D6021
SUT10D6021
Less than 6.5L/min
1.4
Using it safely
This manual and other annexes should be read before installation, operation and maintenance. After being familiar
with all of the precautions and safety information of this equipment, please correctly use it.
1.4.1
Installation and wiring
DANGER
●
Only the qualified personnel can do the wiring work. There is a risk of electrical shock or fire.
●
Wiring worker should take safety measures, such as wearing long sleeves and gloves, for injury prevention.
●
Wiring worker should take safety measures , such as wearing long sleeves and gloves, to prevent electric
shock or fire due to static electricity.
●
Please wire after completing the installation. There is a risk of electrical shock or fire.
●
Please wire after turning OFF the input power. There is a risk of electrical shock.
●
If there is necessary to wire again after the power is turning ON, please make sure the motor is stopped and
the input power is turned OFF 5 minutes or more. There is a risk of electrical shock.
●
Connect the no-fuse breaker and electric leakage breaker that conforms to EN60947-2 to the power supply
line. There is a risk of electrical shock or fire. Please refer to the "9.2 Breaker Installation " for breaker
capacity information.
●
Please connect the ground terminal by the D class grounding method (formerly Class 3 grounding) . There is a
risk of electrical shock or fire.
●
Please prevent the screws, conductive materials (for example metal piece), wood chips, flammable matter (oil)
entering the internal controller. There is a risk of electric shock, fire, or accident.
●
Please do not use it near water or flammable materials, or in corrosive atmosphere or atmosphere of
inflammable gas. There is a risk of electric shock or fire.
●
Do not scratch or apply force to the harness, and do not place heavy objects on the harness, pinch or bend it.
There is a risk of electric shock or damage.
●
Please use the eye bolt to move the product. There is a danger of falling, if lift it by pump piping.
●
Please do not operate or install this product if this product lost parts or damaged.
There is a risk of accident.
●
There is an orifice check valve in the discharge line in this hydraulic unit. It is important to set a pressure
release circuit, if the high response performance, such as pressure relief, is required.
In addition, if the volume
of the load side is large, at the time of shutdown, the fluid sound may be generated from the orifice portion.
But it is not a malfunction.
CAUTION
●
Please make sure the installation environment meets the requirements. There is a risk of fire or accident.
●
Please install in somewhere can withstand its weight. There is a risk of accident.
●
Please do not apply static electricity to terminals. There is a risk of accident.
Summary of Contents for SUT06S3016-30
Page 2: ......
Page 12: ......
Page 20: ...PIM00413 3 6 3 4 Dimensions Motor Pump Type SUT00 SUT00S3016 30...
Page 21: ...PIM00413 3 7 SUT00S6007 30...
Page 22: ...PIM00413 3 8 SUT00D4016 30 SUT00D6021 30 Product type Dimension...
Page 23: ...PIM00413 3 9 Unit Type SUT06 SUT10 SUT06S3016 30...
Page 24: ...PIM00413 3 10 SUT06S6007 30...
Page 25: ...PIM00413 3 11 SUT06D4016 30 SUT06D6021 30 1 327 for SUT06D6021 30 2 188 for SUT06D6021 30 2...
Page 26: ...PIM00413 3 12 SUT10D6021 30...
Page 36: ......
Page 38: ......
Page 42: ......
Page 54: ......
Page 64: ......