PIM00413
8-4
8.2
Filling hydraulic oil (Only SUT06, SUT10)
●
Remove the cap of the oil filling port (air breather) by turning it counterclockwise, and fill clean hydraulic oil
(pollution degree: NAS Class 9 or lower level) into the tank. Set the oil level so that the float of the level gauge
is between the red and yellow lines.
●
Use the hydraulic oil conforming to the specifications. Refer to "3.2.2 Common Specifications "
●
Make sure that the stop valve is opened.
Oil level
gauge
Stop valve
Please open it when using
(horizontal lever: Open, vertical lever: closed)
The stop valve is open
CAUTION
●
Operating the hydraulic unit with no oil in the tank or closing the stop valve causes pump seizure or wear,
which may result in pump damage.
●
During initial operation of the machine, oil will be supplied into the hydraulic circuit of the machine. Be
careful about a decrease in oil level in the tank.
●
The oil level in the tank may largely fluctuate depending on the machine hydraulic circuit. This may result in
oil leak from the tank, or decrease in oil level. Please adjust the oil amount to be an optimal value while
watching the oil level meter.
Summary of Contents for SUT06S3016-30
Page 2: ......
Page 12: ......
Page 20: ...PIM00413 3 6 3 4 Dimensions Motor Pump Type SUT00 SUT00S3016 30...
Page 21: ...PIM00413 3 7 SUT00S6007 30...
Page 22: ...PIM00413 3 8 SUT00D4016 30 SUT00D6021 30 Product type Dimension...
Page 23: ...PIM00413 3 9 Unit Type SUT06 SUT10 SUT06S3016 30...
Page 24: ...PIM00413 3 10 SUT06S6007 30...
Page 25: ...PIM00413 3 11 SUT06D4016 30 SUT06D6021 30 1 327 for SUT06D6021 30 2 188 for SUT06D6021 30 2...
Page 26: ...PIM00413 3 12 SUT10D6021 30...
Page 36: ......
Page 38: ......
Page 42: ......
Page 54: ......
Page 64: ......