PIM00413
12-11
12.4.2
[P39: DO_S] Digital output selection
By changing the parameter "P39: Digital output selection ", the function of digital output DO1 can be selected.
■
Digital output DO1 selection
P39: Digital output selection
Function
Description
0
PQ number switching
completion output
When switch the PQ selection number, if the pressure
command, flow rate command reach the goal, it will
become ON.
1
Motor running output
It will become ON when the motor power is on.
2
High-pressure side
running output
It will become ON, if only the high pressure side runs.
3
(Reserved for system)
(Reserved for system)
4
Pressure and flow
coincidence output
It will become ON, when the flow rate or pressure
match.
5
Pressure coincidence
output
It will become ON , when the pressure matches.
6
Flow rate coincidence
output
It will become ON , when the flow rate matches.
7
Fully charged Output
It will become ON, if the main circuit is charged fully.
■
Pressure coincidence / Flow rate coincidence detection
The current pressure and flow rate can be detected, when the pressure or flow rate command value is within a
certain range.
The coincidence detection range, by setting a percentage of the command value, is limited by the coincidence
detection minimum.
No. Sign
Name
Range
Factory Default
Setting
Unit
P41 PCMW
Pressure coincidence
detection range
0
〜
99
5 %
P42 PCMM
The minimum value of
pressure coincidence
detection
0.0
〜
99.9
0.1 MPa
P43 QCMW
Flow rate coincidence
detection range
0
〜
99
5 %
P44 QCMM
The minimum value of
flow rate coincidence
detection
0.0
〜
99.9
0.2 L/min
Pressure [MPa]
Pressure command×「P25:Pressure
coincidence detection range」/100
Pressure Command
「P26:The minimum value of
pressure coincidence detection」
「P26:The minimum value of
pressure coincidence detection」
Pressure command×「P25:Pressure
coincidence detection range」/100
Summary of Contents for SUT06S3016-30
Page 2: ......
Page 12: ......
Page 20: ...PIM00413 3 6 3 4 Dimensions Motor Pump Type SUT00 SUT00S3016 30...
Page 21: ...PIM00413 3 7 SUT00S6007 30...
Page 22: ...PIM00413 3 8 SUT00D4016 30 SUT00D6021 30 Product type Dimension...
Page 23: ...PIM00413 3 9 Unit Type SUT06 SUT10 SUT06S3016 30...
Page 24: ...PIM00413 3 10 SUT06S6007 30...
Page 25: ...PIM00413 3 11 SUT06D4016 30 SUT06D6021 30 1 327 for SUT06D6021 30 2 188 for SUT06D6021 30 2...
Page 26: ...PIM00413 3 12 SUT10D6021 30...
Page 36: ......
Page 38: ......
Page 42: ......
Page 54: ......
Page 64: ......