PIM00413
3-3
CAUTION
When shipped from the factory, the maximum flow rate was set. [Low pressure (confluence) side flow rate
setting value]
Though the pressure and flow rate can be set beyond the adjustment range, please be sure to use it within the
pressure range and flow rate range.
The high-pressure safety valve is installed in this hydraulic unit, and pressure is set as shown in the following
table.
Product type
High pressure safety valve setting pressure
SUT00S6007 / SUT06S6007
Maximum working pr 0.5MPa
(7.5MPa)
SUT00S3016 / SUT06S3016
SUT00D4016 / SUT06D4016
Maximum working pr 2.0MPa
(18.0MPa)
SUT00D6021 / SUT06D6021
SUT10D6021
Maximum working pr 2.0MPa
(22.6MPa)
However, if it is necessary to minimize the surge pressure of actuator operation, please make adjustments in
accordance with the "13.8 high-pressure safety valve adjustment procedure".
If it continuously operate at the highest pressure, please follow the flow rate requirement showing in the table
below.
Product type
Flow rate
SUT00S3016 / SUT06S3016
5.0L/min or less
SUT00S6007 / SUT06S6007
14.0L/min or less
SUT00D4016 / SUT06D4016
8.0L/min or less
SUT00D6021 / SUT06D6021
SUT10D6021
6.5L/min or less
Please check product specifications (in the format drawing) for other specifications.
Summary of Contents for SUT06S3016-30
Page 2: ......
Page 12: ......
Page 20: ...PIM00413 3 6 3 4 Dimensions Motor Pump Type SUT00 SUT00S3016 30...
Page 21: ...PIM00413 3 7 SUT00S6007 30...
Page 22: ...PIM00413 3 8 SUT00D4016 30 SUT00D6021 30 Product type Dimension...
Page 23: ...PIM00413 3 9 Unit Type SUT06 SUT10 SUT06S3016 30...
Page 24: ...PIM00413 3 10 SUT06S6007 30...
Page 25: ...PIM00413 3 11 SUT06D4016 30 SUT06D6021 30 1 327 for SUT06D6021 30 2 188 for SUT06D6021 30 2...
Page 26: ...PIM00413 3 12 SUT10D6021 30...
Page 36: ......
Page 38: ......
Page 42: ......
Page 54: ......
Page 64: ......