background image

Model

MS-510

Instruction Manual

4179-7 Harvester Road

Burlington, Ontario, Canada

L7L 5M4

Phone: (905) 639-0909  

 

 

 

 

 

Fax: (905) 639-0919

E-mail: [email protected]

Summary of Contents for MS-510

Page 1: ...Model MS 510 Instruction Manual 4179 7 Harvester Road Burlington Ontario Canada L7L 5M4 Phone 905 639 0909 Fax 905 639 0919 E mail info millenniumsignatures com ...

Page 2: ...ated from 0 2 to 2 4 seconds to automatically control power pulsing Foot Pedal Manual or Automatic Operator Selection High Power indicator light 2 3 0 Amp Fuses for power unit protection against overloading Smooth action Power Selection Switch Built in alarm to alert the operator of amperage overload Two individual Rotary Time Selectors NOTE Avoid short circuits See illustration 1 A Do not cross t...

Page 3: ...ures 9 11 5 4 1 10 respectively Illustration 3 A Turn the power unit on Choose the proper current setting AC produces a black mark DC produces a white mark and is also used for deep etching A white mark may be desirable for etching various materials such as black oxide B The 510 B Power Unit is equipped with twelve power settings With the voltage switch Fig 5 set to LOW the settings on the POWER S...

Page 4: ...ropriate monopad on the marking head and attach the insert stencil cap stencil or flat stencil as required E Place the long tube from the 152 electrolyte pump in the open bottle of electrolyte Prime the pump by rotating quickly clockwise The pump is adjusted by the small set screw on the stop below the lever SEMI AUTOMATIC OPERATION A Flip the power toggle switch up to turn the unit on B Choose th...

Page 5: ...ON controls the length of time the current is delivered to the marking head The dial marked OFF controls the length of time the current flow is interrupted even through the marking head remains in contact with the substrate The greater the number the longer the times in both cases An amp meter FIG 8 has been provided for visual confirmation of the current These timers are used for applications tha...

Page 6: ...main up for the selected time and then repeat this cycle until the machine is shut off HOUSEKEEPING It is important to keep your unit free of oxidation and salt build up This will ensure years of dependable trouble free operation A Keep the cord ends alligator plug marking heads and grounds clean If corrosion appears use a light abrasive such as an emery cloth to clean it off B To prevent corrosio...

Page 7: ...DE monopad for best results G Place the stencil over the pad with the reading face down as if to read the information from the bottom of the fixture Slide the O ring over the stencil pad and top plate until it snaps into the machined groove H Connect the hand ground flat bottom or knife edge to the ground jack of your power unit I Place the substrate surface to be marked on the stencil in front of...

Reviews: