PIM00413
13-1
Chapter 13 Troubleshooting
13.1
Protection function
13.1.1
Output signal of the protection function
The table below is output signal of the protection function, depending on the setting of parameter "P08: Alarm
output mix".
○
: Circuit is conducting ×: Circuit is not conducting
P08:
Alarm output mix
0: Individual output
2: Pressure switch function expansion
1: Integrated output
Relay output
Relay output
Alarm Description
A contact
B contact
Digital output
DO2
A
contact
B contact
Digital output
DO2
Power OFF
×
○
× ×
○
×
Power ON: Normal
○
×
○
○
×
×
Alarm occurs
Indefinite Indefinite
×
×
○
×
L63: Pressure switch
operation
×
○
○
×
○
×
Warning occurs
○
×
(*1)
×
○
×
(*1) : It depends on the setting of ”P07: Warning output level setting”. Please refer to "12.4.1 Parameters" for more
information.
13.1.2
Alarm
If the protection function is activated, the alarm will be raised. And the alarm code below will be displayed on the
operation panel.
If an alarm occurs, the pump will be stopped, and the alarm signal will be output.
Please refer to the "13.1.1 Output
signal of the protection function " for more information.
◆ Alarm reason and countermeasures
Alarm
Code
Name Reason
Countermeasure
Layer short of the motor coil
・
Replace the motor pump
Short circuit of the motor
・
Replace the motor pump
Damage of the controller
・
Replace the controller
Encoder connector is
disconnected
・
Connect the encoder connector
Damage of the encoder harness
・
Replace the encoder harness
E09
Output device error 1
Overcurrent protection of the output
device is activated
Failure of the encoder
・
Replace the motor pump
Layer short of the motor coil
・
Replace the motor pump
Short circuit of the motor
・
Replace the motor pump
Damage of the controller
・
Replace the controller
Encoder connector is
disconnected
・
Connect the encoder connector
Damage of the encoder harness
・
Replace the encoder harness
E10
Output device error 2
Overcurrent protection of the output
device is activated
Failure of the encoder
・
Replace the motor pump
Encoder connector is
disconnected
・
Connect the encoder connector
E11
Instantaneous overcurrent
Motor output current exceeded the
specified value
Damage of the encoder harness
・
Replace the encoder harness
Summary of Contents for SUT06S3016-30
Page 2: ......
Page 12: ......
Page 20: ...PIM00413 3 6 3 4 Dimensions Motor Pump Type SUT00 SUT00S3016 30...
Page 21: ...PIM00413 3 7 SUT00S6007 30...
Page 22: ...PIM00413 3 8 SUT00D4016 30 SUT00D6021 30 Product type Dimension...
Page 23: ...PIM00413 3 9 Unit Type SUT06 SUT10 SUT06S3016 30...
Page 24: ...PIM00413 3 10 SUT06S6007 30...
Page 25: ...PIM00413 3 11 SUT06D4016 30 SUT06D6021 30 1 327 for SUT06D6021 30 2 188 for SUT06D6021 30 2...
Page 26: ...PIM00413 3 12 SUT10D6021 30...
Page 36: ......
Page 38: ......
Page 42: ......
Page 54: ......
Page 64: ......