![background image](http://html1.mh-extra.com/html/daikin/super-multi-plus-e-series-ftxg25ev1bw/super-multi-plus-e-series-ftxg25ev1bw_service-manual_4705813467.webp)
SiBE18-821_C
BP Unit
Removal Procedure
455
3
Disconnect the
connectors for the
electronic expansion
valve [X20A] [X21A]
[X22A] [X23A] and the
connector for the
thermistors [X90A].
[X20A]: bypass
[X21A]: for room A
[X22A]: for room B
[X23A]: for room C
BPMKS967B2B model does
not have [X23A].
4
Remove the screw of
the wire harness band.
5
Remove the screw of
the earth.
Step
Procedure
Points
(R12988)
[X23A]
[X90A]
[X22A]
[X21A]
[X20A]
(Q0505)
Wire harness band
(R12989)