Functions
SiBE18-821_C
8
List of Functions
Category
Functions
FF
Q25/
35/
50/
60B
8
V
1B
FCQ
3
5/
50/
60C7V
E
B
Category
Functions
FF
Q25/
35/
50/
60B
8
V
1B
FCQ
3
5/
50/
60C7V
E
B
Basic
Function
Inverter (with Inverter Power Control)
{
{
Health &
Clean
Air-Purifying Filter
—
—
Operation Limit for Cooling (°CDB)
—
—
Photocatalytic Deodorizing Filter
—
—
Operation Limit for Heating (°CWB)
—
—
Air-Purifying Filter with Photocatalytic
Deodorizing Function
—
—
PAM Control
—
—
Titanium Apatite Photocatalytic
Air-Purifying Filter
—
—
Standby Electricity Saving
—
—
Compressor
Oval Scroll Compressor
—
—
Longlife Filter
{
{
Swing Compressor
—
—
Wipe-Clean Flat Panel
—
—
Rotary Compressor
—
—
Washable Grille
{
{
Reluctance DC Motor
—
—
Filter Cleaning Indicator
{
{
Comfortable
Airflow
Power-Airflow Flap
—
—
MOLD PROOF Operation
—
—
Power-Airflow Dual Flaps
—
—
Good-Sleep Cooling Operation
—
—
Power-Airflow Diffuser
—
—
Timer
Schedule Timer Operation
{
★
2
{
★
2
Wide-Angle Louvers
—
—
72-Hour ON/OFF TIMER
{
★
1
{
★
1
Vertical Auto-Swing (Up and Down)
{
{
NIGHT SET Mode
—
—
Horizontal Auto-Swing (Right and Left)
—
—
Worry Free
“Reliability &
Durability”
Auto-Restart (after Power Failure)
{
{
3-D Airflow
—
—
Self-Diagnosis (Digital, LED) Display
{
{
COMFORT AIRFLOW Operation
—
—
Wiring Error Check Function
—
—
Comfort
Control
Auto Fan Speed
—
—
Anti-Corrosion Treatment of Outdoor
Heat Exchanger
—
—
Indoor Unit Quiet Operation
—
—
Flexibility
Multi-Split / Split Type Compatible
Indoor Unit
{
{
NIGHT QUIET Mode (Automatic)
—
—
H/P, C/O Compatible Indoor Unit
{
{
OUTDOOR UNIT QUIET Operation
(Manual)
—
—
Flexible Power Supply Correspondence
—
—
2-Area INTELLIGENT EYE Operation
—
—
High Ceiling Application
—
{
INTELLIGENT EYE Operation
—
—
Chargeless
—
—
Quick Warming Function
(Preheating Operation)
—
—
Either Side Drain (Right or Left)
—
—
Hot-Start Function
{
{
Power Selection
—
—
Automatic Defrosting
—
—
Remote
Control
5-Room Centralized Controller (Option)
—
—
Operation
Automatic Operation
{
{
Program Dry Operation
{
{
Remote Control Adaptor
(Normal Open Pulse Contact) (Option)
—
—
Fan Only
{
{
Lifestyle
Convenience
New POWERFUL Operation
(Non-Inverter)
—
—
Remote Control Adaptor
(Normal Open Contact) (Option)
—
—
Inverter POWERFUL Operation
—
—
DIII-NET Compatible (Adaptor) (Option)
{
{
Priority-Room Setting
—
—
Remote
Controller
Wireless (Option)
{
{
COOL / HEAT Mode Lock
—
—
Wired (Option)
{
{
HOME LEAVE Operation
—
—
ECONO Operation
—
—
Indoor Unit ON/OFF Button
{
★
1
{
★
1
Signal Receiving Sign
{
★
1
{
★
1
Temperature Display
—
—
Note:
{
: Holding Functions
— : No Functions
★
1:
★
2:
with wireless remote controller