SiENBE04-808_A
Outdoor Unit - RK(X)S42G2V1B, ARXS42G2V1B
Removal Procedure
258
Note:
Do not use a metal saw for
cutting pipes by all means
because the sawdust comes
into the circuit.
When withdrawing the pipes,
be careful not to pinch them
firmly with pliers. The pipes
may get deformed.
Provide a protective sheet or
a steel plate so that the
brazing flame cannot
influence peripheries.
Step
Procedure
Points
(R8209)
SiENBE04-808_A.pdf 270