Outdoor Unit - RK(X)S20-35G2V1B9, ARXS20-35G3V1B
SiENBE04-808_A
233
Removal Procedure
3.6
Removal of Four Way Valve
Procedure
Warning
Be sure to wait 10 minutes or more after turning off all power supplies
before disassembling work.
Step
Procedure
Points
1
Pull out the electronic
expansion valve coil.
2
Remove the terminal
cover.
3
Disconnect the lead
wires of the
compressor.
(R7233)
Electronic
expansion
valve coil
(R7234)
Terminal cover
V
W
U
(R7235)
Red (U)
Yellow (V)
Blue (W)
SiENBE04-808_A.pdf 245