SiENBE04-808_A
Functions
List of Functions
2
1. Functions
1.1
Cooling Only
Category
Functions
FT
XS20/25/35/42G2V1B
RKS20/25/3
5/42G2V1B
RKS20/25/3
5G2V1B9
F
T
X
S
5
0
G
2V
1B
RKS50G2V1B
Category
Functions
FT
XS20/25/35/42G2V1B
RKS20/25/3
5/42G2V1B
RKS20/25/3
5G2V1B9
F
T
X
S
5
0
G
2V
1B
RKS50G2V1B
Basic
Function
Inverter
(with Inverter Power Control)
{
{
Health &
Clean
Air-Purifying Filter
—
—
Operation Limit for Cooling (°CDB)
–10
~46
H
–10
~46
H
Photocatalytic Deodorizing Filter
—
—
Operation Limit for Heating (°CWB)
—
—
Air-Purifying Filter with
Photocatalytic Deodorizing Function
—
—
PAM Control
{
{
Standby Electricity Saving
{
—
Titanium Apatite Photocatalytic
Air-Purifying Filter
{
{
Compressor
Oval Scroll Compressor
—
—
Swing Compressor
{
{
Air Filter (Prefilter)
{
{
Rotary Compressor
—
—
Wipe-Clean Flat Panel
{
{
Reluctance DC Motor
{
{
Washable Grille
—
—
Comfortable
Airflow
Power-Airflow Flap
—
—
MOLD PROOF Operation
—
—
Power-Airflow Dual Flaps
{
{
Good-Sleep Cooling Operation
—
—
Power-Airflow Diffuser
—
—
Timer
WEEKLY TIMER Operation
{
{
Wide-Angle Louvers
{
{
24-Hour ON/OFF TIMER
{
{
Vertical Auto-Swing (Up and Down)
{
{
NIGHT SET Mode
{
{
Horizontal Auto-Swing
(Right and Left)
{
{
Worry Free
“Reliability &
Durability”
Auto-Restart (after Power Failure)
{
{
3-D Airflow
{
{
Self-Diagnosis (Digital, LED)
Display
{
{
COMFORT AIRFLOW Operation
{
{
Wiring Error Check
—
—
Comfort
Control
Auto Fan Speed
{
{
Anti-Corrosion Treatment of
Outdoor Heat Exchanger
{
{
Indoor Unit Quiet Operation
{
{
Flexibility
Multi-Split / Split Type Compatible
Indoor Unit
{
{
NIGHT QUIET Mode (Automatic)
—
—
H/P, C/O Compatible Indoor Unit
{
{
OUTDOOR UNIT QUIET Operation
(Manual)
{
{
Flexible Voltage Correspondence
—
—
2-Area INTELLIGENT EYE Operation
{
{
High Ceiling Application
—
—
INTELLIGENT EYE Operation
—
—
Chargeless
10 m
10 m
Quick Warming Function
(Preheating Operation)
—
—
Either Side Drain (Right or Left)
{
{
Hot-Start Function
—
—
Power Selection
—
—
Automatic Defrosting
—
—
Remote
Control
5-Rooms Centralized Controller
(Option)
{
{
Operation
Automatic Operation
—
—
Remote Control Adapter
(Normal Open Pulse Contact)
(Option)
{
{
Program Dry Operation
{
{
Fan Only
{
{
Remote Control Adapter
(Normal Open Contact) (Option)
{
{
Lifestyle
Convenience
New POWERFUL Operation
(Non-Inverter)
—
—
DIII-NET Compatible (Adapter)
(Option)
{
{
Inverter POWERFUL Operation
{
{
Remote
Control
Wireless
{
{
Priority-Room Setting
—
—
Wired (Option)
{
{
COOL / HEAT Mode Lock
—
—
HOME LEAVE Operation
—
—
ECONO Operation
{
{
Indoor Unit ON/OFF Button
{
{
Signal Receiving Sign
{
{
Temperature Display
—
—
Note:
{
: Holding Functions
— : No Functions
H
: Lower limit can be extended to –15°C by cutting
jumper (20-42 class) or turning switch (50 class).
(facility use only)
SiENBE04-808_A.pdf 14
21/02/2011 13:19:54