     Allowed refrigerant pipe length and 
     level difference

Max. length

Max. level

difference

Pre charged

*1

30 m

30 m

RQ71L

30 m

30 m

RQ100L

50 m

30 m

30 m

30 m

RQ125L

30 m

RQ140L

Note: 

1

Additional refrigerant charging is required if the

           refrigerant pipe is longer than the length.

OUTDOOR UNIT

Compact Outdoor 
Unit for Round Flow 
Cassette

RQ100LV1A
RQ125LV1A
RQ140LV1A

RQ71LV1A

Easy installation and maintenance

Pre charged for up to 30 metres

4-direction piping offers greater
layout freedom

50 m piping length 

Separation 
available

If refrigerant piping length does not exceed 
30 m, there is no need for on-site gas 
charging.

Effective gas monitoring reduces the labor 
required for operation, maintenance, and 
repairs.

Low gas level detection function

The outer panel for the piping connection 
part of the front, right side and backside 
can be removed 
and is easier for 
post-installation 
piping work. 

NEW

NEW

NEW

NEW

Coating

Casing net plate

Outside air

Average

40   m 

or more

Equivalent length

70 m

50 m

Equivalent length

70 m

50 m

Equivalent length

70 m

50 m

Equivalent length

70 m

A pump-down switch is provided to make 
it easier to collect refrigerant if the unit is to 
be moved or layout modified. 

Facilitates pump down 

(Refrigerant recovery function)

*Pump-down function is available for pre-charged 
refrigerant amount.

-20

-10

0

10

20

30

40

50

Wide operation range

46

˚

CDB

Cooling

-5

˚

CDB

Outdoor temp(˚CWB)

Outdoor temp(˚CDB)

Heating

-10

-10

˚

CWB

CWB

15.5

15.5

˚

CWB

CWB

-10

˚

CWB

15.5

˚

CWB

Cooling is efficient even in winter when 
indoor temperatures are higher than those 
outside, such as in underground public 
spaces or offices with many computers.

Operation range

Suited for year-round cooling 
applications

The maximum capacity is maintained 
within a set level of power 
consumption, which makes it possible 
to keep a comfortable and effective 
demand control.

As the bottom frame is subject to corrosion, 
a corrosion-proof galvarium steel plate is 
adopted to enhance the durability.

Heat exchange fins are provided with anti-
corrosion treatment

Durability

Construction

Non-treated fin

Anti corrosion 
treated heat 
exchangers

Aluminium

Aluminium
Corrosion resistant
acrylic resin  

Hydrophilic film 

8:00

12:00

16:00

20:00

Power 

consumption

Time

Limitation

Demand Control 
Function

* Required for KRP58M51 (Option)

100/125/140L

71L

1,170

770

Height(mm)

98

68

Weight(kg)

900

Width(mm)

320

Depth(mm)

Compact and light weight

Easy centralised installation 
with the module oriented design

A coating of 40   m or more protects the 
outside unit from exposure to rain
and snow.

5

Summary of Contents for SkyAirFCQN-KVEA

Page 1: ...PCSAU0739C HEAT PUMP 50Hz Air Conditioning Systems FCQN KVEA RQ LV1A 360 airflow 360 airflow...

Page 2: ...nd Flow CEILING MOUNTED CASSETTE TYPE OUTDOOR UNIT INDOOR UNIT Series PRODUCT RANGE Round Flow FCQN71KVEA 71 FCQN100KVEA FCQN125KVEA FCQN140KVEA 100 125 140 RQ71LV1A RQ100LV1A RQ125LV1A RQ140LV1A NEW...

Page 3: ...sy to clean Non flocking horizontal louvres Bactericidal treatment for drain pan Helps prevents mould and microorganisms growing out of the dust and moisture that adheres to the filters Filter has ant...

Page 4: ...ings that must be kept spotless Standard setting to prevent draft Standard setting Setting to prevent soiling of ceiling At heating startup and thermo OFF air discharge is automatically set to a near...

Page 5: ...direct connection round duct Outside Note Use of options will increase operating sound The units can be installed in the following different ways Note Some ceiling constructions may hinder installati...

Page 6: ...moved or layout modified Facilitates pump down Refrigerant recovery function Pump down function is available for pre charged refrigerant amount 20 10 0 10 20 30 40 50 Wide operation range 46 CDB Cooli...

Page 7: ...n expanded gas resulting high efficiency compression Night time quiet operation function The Automatic night quiet mode will initiate 8 hours after the peak temperature is reached in the daytime and n...

Page 8: ...arious icons and texts to be displayed smoothly Large text display improves readability Equipped backlight helps operating in dark rooms Dot matrix display Backlight display Available in 10 languages...

Page 9: ...type The wireless remote controller is supplied in a set with a signal receiver Signal receiver unit is contained inside decoration panel or indoor unit Shape of signal receiver unit differs according...

Page 10: ...receiver unit installed on indoor unit HeatReclaimVentilatorforindoorunitswithinazoneareoperatedby interlocking Canalsobeoperatedindependentlybyremotecontroller Central remote controller option Heat...

Page 11: ...ontroller Swing pattern selection Delivers air conditioning comfort all the way down to the floor in air conditioning zones with high ceilings High ceiling application Draft prevention function heatin...

Page 12: ...iping If the refrigerant piping length does not exceed 30 m there is no need for on site gas charging Drain pump mechanism Pre charged for up to 30 metres The filter sign warns you when it is time to...

Page 13: ...5 5 Hermetically sealed scroll type o 26 0 Hole 2 4 3 7 Charged for 30 m I Do 25XO Do 32 33 22 5 12 5 6 3 12 5 14 0 7 0 14 0 FCQN140KVEA RQ140LV1A o 9 5 o 15 9 52 54 dB A Night quiet mode 45 46 46 47...

Page 14: ...the same side to which a fresh air intake kit direct mount is installed Panel grille related Independently installable optional parts Operation control related Auxillary function related Filter relat...

Page 15: ...been damp and troubled under an indoor unit When the case where humidity is 80 or more and the drain outlet are choked up and the air filter are dirty dew may fall 1500 or more required space From the...

Page 16: ...ply wiring intake Control wiring intake Drain outlet 1 2 3 4 5 6 7 8 OUTDOOR UNIT RQ100LV1A 125LV1A 140LV1A OUTDOOR UNIT RQ71LV1A Gas pipe connection Liquid pipe connection Service port Grounding term...

Page 17: ...00 m Type Vinyl cord with sheath or cable insulated thickness 1mm or more Through hole 8 10 Condit Lower case portion Switch box for one switch ex KJB111A optional accessory Switch box for two switch...

Page 18: ...than two units 100 or more 500 or less 1000 or more An obstruction in the overhead space 500 or less 500 or more 1000 or more An obstruction in the overhead space 150 or more 150 or more 150 or more 5...

Page 19: ...MEMO 18...

Page 20: ...subsidiaries in Japan are certified under the ISO 14001 international standard for environment management Warning Daikin products are manufactured for export to numerous countries throughout the worl...

Reviews: