OPTIONS

Outdoor unit

Kit name

KKPJ5F180

K-KYZP15C

KPT-60B160

KRP58M51

RQ71LV1A

RQ100LV1A

RQ125LV1A

RQ140LV1A

Central drain plug
Wire fixture for preventing overturning

Name of option

Fixture for preventing overturning
Demand adaptor

For each flow pattern – all round, 4-way, 3-way, 2-way, branch duct connection – the compatibility of each independently installed option 
(shown in the column on the left) to accessory options (listed across the top of each table) is shown in the cells where the relevant row and column intersect.

A circle (

o

) indicates compatibility,  and a cross (

x

) indicates incompatibility. Any options not shown below are not suitable for independent or accessory installation.

Round flow type: List of optional parts required to achieve different flow patterns

1

In some cases, depending on how the unit is embedded in the ceiling, use of branch ducts and fresh air intake kits may not be possible. Before starting installation work make sure to check 

whether or not joint installation is possible. In particular, ensure that the lower fixing position caused by the addition of panel spacers is acceptable.

2

Use a chamber connection kit if two different types of optional chamber are used together. In this case, the fresh air intake kit must be installed in the upper position.

3

It is not possible to use panel spacers in a 2-way flow installation. 

4

It is not possible to install a branch duct on the same side to which a fresh air intake kit (direct mount) is installed.

Panel/grille related

Independently installable optional parts

Operation control related
Auxillary function related

Filter related

Optional accessory parts

Independently installable optional parts

Optional accessory parts

Independently installable optional parts

Optional accessory parts

Panel spacer

1

Panel spacer

1

o

o

o

x

Wireless remote controller

o

o

o

o

Fresh air intake kit (direct mount)

o

o

o

o

x

o

o

x

High-efficiency filter

2

o

o

o

x

High-humidity operation kit

Panel/grille related
Operation control related
Auxillary function related

Panel spacer

1

Wireless remote controller

Fresh air intake kit (direct mount)
High-humidity operation kit

All-round flow  4-way flow

 o

3

 o

3

x

x

 o

3

o

x

x

x

o

 o

3

o

x

x

o

x

o

o

3-way flow  2-way flow

1-way branch / unit 3-way flow

Branch duct

1

(Chamber type)
(Round duct type)

o

o

 

o

4

x

x

2-way branch / unit 2-way flow
1-way branch / unit 2-way flow

x

o

 

o

4

x

x

x

o

 

o

4

x

x

Branch duct connection

Wireless 

remote controller

Fresh air intake kit 

(direct mount)

High-efficiency

 filter

2

 

High-humidity 

operation kit

Panel spacer

1

Wireless 

remote controller

Fresh air intake kit 

(direct mount)

High-efficiency

 filter

2

 

High-humidity 

operation kit

Panel spacer

1

Wireless 

remote controller

Fresh air intake kit 

(direct mount)

Fresh air intake kit (

Chamber type

)

1,2

o

o

o

x

Fresh air intake kit (

Chamber type

)

1,2

 o

3

o

x

x

o

o

x

o

 o

3

o

x

x

x

 o

 o

 o

Fresh air intake kit 

(Chamber type)

1,2

Fresh air intake kit 

(Chamber type)

1,2

Fresh air intake kit 

(Chamber type)

1,2

High-efficiency

 filter

2

 

High-humidity 

operation kit

13

Summary of Contents for SkyAirFCQN-KVEA

Page 1: ...PCSAU0739C HEAT PUMP 50Hz Air Conditioning Systems FCQN KVEA RQ LV1A 360 airflow 360 airflow...

Page 2: ...nd Flow CEILING MOUNTED CASSETTE TYPE OUTDOOR UNIT INDOOR UNIT Series PRODUCT RANGE Round Flow FCQN71KVEA 71 FCQN100KVEA FCQN125KVEA FCQN140KVEA 100 125 140 RQ71LV1A RQ100LV1A RQ125LV1A RQ140LV1A NEW...

Page 3: ...sy to clean Non flocking horizontal louvres Bactericidal treatment for drain pan Helps prevents mould and microorganisms growing out of the dust and moisture that adheres to the filters Filter has ant...

Page 4: ...ings that must be kept spotless Standard setting to prevent draft Standard setting Setting to prevent soiling of ceiling At heating startup and thermo OFF air discharge is automatically set to a near...

Page 5: ...direct connection round duct Outside Note Use of options will increase operating sound The units can be installed in the following different ways Note Some ceiling constructions may hinder installati...

Page 6: ...moved or layout modified Facilitates pump down Refrigerant recovery function Pump down function is available for pre charged refrigerant amount 20 10 0 10 20 30 40 50 Wide operation range 46 CDB Cooli...

Page 7: ...n expanded gas resulting high efficiency compression Night time quiet operation function The Automatic night quiet mode will initiate 8 hours after the peak temperature is reached in the daytime and n...

Page 8: ...arious icons and texts to be displayed smoothly Large text display improves readability Equipped backlight helps operating in dark rooms Dot matrix display Backlight display Available in 10 languages...

Page 9: ...type The wireless remote controller is supplied in a set with a signal receiver Signal receiver unit is contained inside decoration panel or indoor unit Shape of signal receiver unit differs according...

Page 10: ...receiver unit installed on indoor unit HeatReclaimVentilatorforindoorunitswithinazoneareoperatedby interlocking Canalsobeoperatedindependentlybyremotecontroller Central remote controller option Heat...

Page 11: ...ontroller Swing pattern selection Delivers air conditioning comfort all the way down to the floor in air conditioning zones with high ceilings High ceiling application Draft prevention function heatin...

Page 12: ...iping If the refrigerant piping length does not exceed 30 m there is no need for on site gas charging Drain pump mechanism Pre charged for up to 30 metres The filter sign warns you when it is time to...

Page 13: ...5 5 Hermetically sealed scroll type o 26 0 Hole 2 4 3 7 Charged for 30 m I Do 25XO Do 32 33 22 5 12 5 6 3 12 5 14 0 7 0 14 0 FCQN140KVEA RQ140LV1A o 9 5 o 15 9 52 54 dB A Night quiet mode 45 46 46 47...

Page 14: ...the same side to which a fresh air intake kit direct mount is installed Panel grille related Independently installable optional parts Operation control related Auxillary function related Filter relat...

Page 15: ...been damp and troubled under an indoor unit When the case where humidity is 80 or more and the drain outlet are choked up and the air filter are dirty dew may fall 1500 or more required space From the...

Page 16: ...ply wiring intake Control wiring intake Drain outlet 1 2 3 4 5 6 7 8 OUTDOOR UNIT RQ100LV1A 125LV1A 140LV1A OUTDOOR UNIT RQ71LV1A Gas pipe connection Liquid pipe connection Service port Grounding term...

Page 17: ...00 m Type Vinyl cord with sheath or cable insulated thickness 1mm or more Through hole 8 10 Condit Lower case portion Switch box for one switch ex KJB111A optional accessory Switch box for two switch...

Page 18: ...than two units 100 or more 500 or less 1000 or more An obstruction in the overhead space 500 or less 500 or more 1000 or more An obstruction in the overhead space 150 or more 150 or more 150 or more 5...

Page 19: ...MEMO 18...

Page 20: ...subsidiaries in Japan are certified under the ISO 14001 international standard for environment management Warning Daikin products are manufactured for export to numerous countries throughout the worl...

Reviews: