OPTIONS
Outdoor unit
Kit name
KKPJ5F180
K-KYZP15C
KPT-60B160
KRP58M51
RQ71LV1A
RQ100LV1A
RQ125LV1A
RQ140LV1A
Central drain plug
Wire fixture for preventing overturning
Name of option
Fixture for preventing overturning
Demand adaptor
For each flow pattern – all round, 4-way, 3-way, 2-way, branch duct connection – the compatibility of each independently installed option
(shown in the column on the left) to accessory options (listed across the top of each table) is shown in the cells where the relevant row and column intersect.
A circle (
o
) indicates compatibility, and a cross (
x
) indicates incompatibility. Any options not shown below are not suitable for independent or accessory installation.
Round flow type: List of optional parts required to achieve different flow patterns
1
In some cases, depending on how the unit is embedded in the ceiling, use of branch ducts and fresh air intake kits may not be possible. Before starting installation work make sure to check
whether or not joint installation is possible. In particular, ensure that the lower fixing position caused by the addition of panel spacers is acceptable.
2
Use a chamber connection kit if two different types of optional chamber are used together. In this case, the fresh air intake kit must be installed in the upper position.
3
It is not possible to use panel spacers in a 2-way flow installation.
4
It is not possible to install a branch duct on the same side to which a fresh air intake kit (direct mount) is installed.
Panel/grille related
Independently installable optional parts
Operation control related
Auxillary function related
Filter related
Optional accessory parts
Independently installable optional parts
Optional accessory parts
Independently installable optional parts
Optional accessory parts
Panel spacer
1
Panel spacer
1
o
o
o
x
Wireless remote controller
o
o
o
o
Fresh air intake kit (direct mount)
o
o
o
o
x
o
o
x
High-efficiency filter
2
o
o
o
x
High-humidity operation kit
Panel/grille related
Operation control related
Auxillary function related
Panel spacer
1
Wireless remote controller
Fresh air intake kit (direct mount)
High-humidity operation kit
All-round flow 4-way flow
o
3
o
3
x
x
o
3
o
x
x
x
o
o
3
o
x
x
o
x
o
o
3-way flow 2-way flow
1-way branch / unit 3-way flow
Branch duct
1
(Chamber type)
(Round duct type)
o
o
o
4
x
x
2-way branch / unit 2-way flow
1-way branch / unit 2-way flow
x
o
o
4
x
x
x
o
o
4
x
x
Branch duct connection
Wireless
remote controller
Fresh air intake kit
(direct mount)
High-efficiency
filter
2
High-humidity
operation kit
Panel spacer
1
Wireless
remote controller
Fresh air intake kit
(direct mount)
High-efficiency
filter
2
High-humidity
operation kit
Panel spacer
1
Wireless
remote controller
Fresh air intake kit
(direct mount)
Fresh air intake kit (
Chamber type
)
1,2
o
o
o
x
Fresh air intake kit (
Chamber type
)
1,2
o
3
o
x
x
o
o
x
o
o
3
o
x
x
x
o
o
o
Fresh air intake kit
(Chamber type)
1,2
Fresh air intake kit
(Chamber type)
1,2
Fresh air intake kit
(Chamber type)
1,2
High-efficiency
filter
2
High-humidity
operation kit
13