LCD REMOTE CONTROLLER

Central remote controller

Interface adaptor for SkyAir series

Easily adaptable to large-scale, high-function, centralised remote control system.

Centralised control, with a setting as 
simple as it is with a standard
remote controller, of up to 64 groups 
(1,024 indoor units) is possible.

DCS302CA61

 (Option)

DTA112BA51

 (Option)

With its high functionality, the full 
colour “all-in-one” graphic controller 
facilitates management of SkyAir 
System in a variety of ways.

DCS601C51

 (Option)

Unified on/off controller

Centralised control of on/off by 
group or all at once for up to 256 
indoor units.

DCS301BA61

 (Option)

Schedule timer

Unified control of weekly schedule 
for up to 1,024 indoor units.

DST301BA61

 (Option)

Schedule timer sets on/off time in 1 minute units 
to be executed twice a day for a week at a time.

Simple system provides a diverse assortment of control modes.

Control by 1

remote controller

Control pattern

Wired remote controller

Wireless remote controller

Control by 2

remote controllers

Group control

Control by 

external command

Centralised remote

control

Interlock control

with Heat Reclaim 

Ventilator

(Basic system)

Link by remote 
controller group control.

Zone link control by 
centralised control.

For control from 2 
locations such as in 
room and control room, 
exits, etc.

For simultaneous 
control of up to 16 
indoor units.

Centralised control of 
up to 64 indoor groups 
from remote location
up to 1 kilometer away.

Not possible

Signal receiver unit installed 
on indoor unit

Heat Reclaim Ventilator for indoor units within a zone are operated by 
interlocking. Can also be operated independently by remote controller.

Central remote controller (option)

Heat Reclaim 

Ventilator

Can be operated simultaneously 
or independently by remote controller
 (set by ventilation mode)

Heat Reclaim 

Ventilator

Central remote controller (option)

Non-polar, double-core 
(max. wiring length 500 m)

Connects 2 wired 
remote controllers

Automatic address setting function

Automatic address setting function

Signal receiver unit installed 
on 1 indoor unit

Optional wiring adaptor for 
electrical appendices is necessary

Central remote controller (option)

Can be operated simultaneously 
by remote controller 
(set by ventilation mode)

Heat Reclaim 

Ventilator

Heat Reclaim Ventilator for indoor units within 
a zone are operated by interlocking

Central remote controller (option)

Heat Reclaim 

Ventilator

Operation and 
surveillance is carried out 
using the contact signal 
from the operation control 
box in the building 
surveillance (security) 
room.

Optional wiring adaptor for 
electrical appendices is necessary

Optional SkyAir series interface 
adaptor required.

Optional SkyAir series interface 
adaptor required.

Note: When a wireless remote controller is used, remote control by two remote controllers is not possible.

Enables centralised control via connection 
to a high-speed, DIII-NET communication 
system, adopted for the Daikin VRV system.

Necessary for interface adaptor for SkyAir series with the 
central remote control units shown at above.

The interface adaptor for the SkyAir series is 
optional except for the ceiling mounted cassette 
type.

9

Summary of Contents for SkyAirFCQN-KVEA

Page 1: ...PCSAU0739C HEAT PUMP 50Hz Air Conditioning Systems FCQN KVEA RQ LV1A 360 airflow 360 airflow...

Page 2: ...nd Flow CEILING MOUNTED CASSETTE TYPE OUTDOOR UNIT INDOOR UNIT Series PRODUCT RANGE Round Flow FCQN71KVEA 71 FCQN100KVEA FCQN125KVEA FCQN140KVEA 100 125 140 RQ71LV1A RQ100LV1A RQ125LV1A RQ140LV1A NEW...

Page 3: ...sy to clean Non flocking horizontal louvres Bactericidal treatment for drain pan Helps prevents mould and microorganisms growing out of the dust and moisture that adheres to the filters Filter has ant...

Page 4: ...ings that must be kept spotless Standard setting to prevent draft Standard setting Setting to prevent soiling of ceiling At heating startup and thermo OFF air discharge is automatically set to a near...

Page 5: ...direct connection round duct Outside Note Use of options will increase operating sound The units can be installed in the following different ways Note Some ceiling constructions may hinder installati...

Page 6: ...moved or layout modified Facilitates pump down Refrigerant recovery function Pump down function is available for pre charged refrigerant amount 20 10 0 10 20 30 40 50 Wide operation range 46 CDB Cooli...

Page 7: ...n expanded gas resulting high efficiency compression Night time quiet operation function The Automatic night quiet mode will initiate 8 hours after the peak temperature is reached in the daytime and n...

Page 8: ...arious icons and texts to be displayed smoothly Large text display improves readability Equipped backlight helps operating in dark rooms Dot matrix display Backlight display Available in 10 languages...

Page 9: ...type The wireless remote controller is supplied in a set with a signal receiver Signal receiver unit is contained inside decoration panel or indoor unit Shape of signal receiver unit differs according...

Page 10: ...receiver unit installed on indoor unit HeatReclaimVentilatorforindoorunitswithinazoneareoperatedby interlocking Canalsobeoperatedindependentlybyremotecontroller Central remote controller option Heat...

Page 11: ...ontroller Swing pattern selection Delivers air conditioning comfort all the way down to the floor in air conditioning zones with high ceilings High ceiling application Draft prevention function heatin...

Page 12: ...iping If the refrigerant piping length does not exceed 30 m there is no need for on site gas charging Drain pump mechanism Pre charged for up to 30 metres The filter sign warns you when it is time to...

Page 13: ...5 5 Hermetically sealed scroll type o 26 0 Hole 2 4 3 7 Charged for 30 m I Do 25XO Do 32 33 22 5 12 5 6 3 12 5 14 0 7 0 14 0 FCQN140KVEA RQ140LV1A o 9 5 o 15 9 52 54 dB A Night quiet mode 45 46 46 47...

Page 14: ...the same side to which a fresh air intake kit direct mount is installed Panel grille related Independently installable optional parts Operation control related Auxillary function related Filter relat...

Page 15: ...been damp and troubled under an indoor unit When the case where humidity is 80 or more and the drain outlet are choked up and the air filter are dirty dew may fall 1500 or more required space From the...

Page 16: ...ply wiring intake Control wiring intake Drain outlet 1 2 3 4 5 6 7 8 OUTDOOR UNIT RQ100LV1A 125LV1A 140LV1A OUTDOOR UNIT RQ71LV1A Gas pipe connection Liquid pipe connection Service port Grounding term...

Page 17: ...00 m Type Vinyl cord with sheath or cable insulated thickness 1mm or more Through hole 8 10 Condit Lower case portion Switch box for one switch ex KJB111A optional accessory Switch box for two switch...

Page 18: ...than two units 100 or more 500 or less 1000 or more An obstruction in the overhead space 500 or less 500 or more 1000 or more An obstruction in the overhead space 150 or more 150 or more 150 or more 5...

Page 19: ...MEMO 18...

Page 20: ...subsidiaries in Japan are certified under the ISO 14001 international standard for environment management Warning Daikin products are manufactured for export to numerous countries throughout the worl...

Reviews: