CEILING MOUNTED CASSETTE TYPE

DIMENSIONS

(Unit: mm)

950

950

arrow view

A

Pipe Connection

Side

Drain Connection

Side

Note 2

8

6

7

860~910(Ceiling opening space) (Note 4)

710(Suspension position)

420

420

780(Suspension position)

860~910(Ceiling opening space) (Note 4)

300

or less

9

B

C

Liquid pipe connection
Gas pipe connection
Drain pipe connection
Power-source wiring and a unit wiring connection
Connection wiring / remote control wiring connection
Air-outlet
Suction grille
Corner decoration cover
Drain hose (accessory)

1

2

3

4

5

6

7

8

9

1500mm or more

200mm or more

1500mm or more

When the blow-off grille is closing. 

The required space is 500mm or more.

When uniting and closing a corner part

 (both right and left of the blow-off grille to close),

it is 200mm or more.

1500mm

  or more

1500mm

  or more

200mm

or more

Required space

(round shape type)

840

340

80

80

124

55

55

256

124

110

95

40

29

850

175

Adjustable(0~675)

10

246

160

50

165

125

Connection position

of branch duct

(square-shaped type)

4

1

2

2   100=200

16-M4 Prepared hole

Connection position

of branch duct

Suspension bolt
4-M8~M10

C/L

20

157

350

280

330

Notes:

1

Sticking location for manufacture's label

 manufacture's label for indoor unit:
 Suction grille inner side's electric components box's lid surface
 manufacture's label for decoration panel :
 Decoration panel's corner decoration cover inner surface

2

In case of using wireless remote controller, this position will be a signal receiver. Refer to the drawing of wireless remote controller 

in detail.

3

When the temperature and humidity in the ceiling exceed 30

˚

C and RH 80% or the fresh air is inducted into the ceiling or the unit 

continues 24 hour operation, an additional insulation (thickness 10mm or more of glasswool or polyethylene form) is required.

4

Though the installation is acceptable up to maximum of 910mm square ceiling opening, keep the clearance of 35mm or less 

between the indoor unit and the ceiling opening so that

 the panel overlap allowance can be ensured.

5

Please do not place the thing been damp and troubled under an indoor unit.

 When the case where humidity is 80% or more, and the drain outlet are choked up and the air filter are dirty, dew may fall.

1500 or more

(required space)

From the floor side 2500 or more

Connection position

of branch duct
(square-shaped type)

Connection position

of branch duct

(round shape type)

20-M4 Prepared hole

35 or less

(Note 4)

35 or less 

(Note 4)

A

For height installation

81

124

2x100=200

157

124

105

64

55

840

110

350

160

130

95

50

256

5

85

55

60

42

150

3

Connection position

of branch duct

(round shape type)

Connection position

of branch duct

(square-shaped type)

16-M4 Hole

arrow view

B

95

85

350

C/L

124

81

110

160

2x100=200

124

157

[FCQN71KVEA]

20-M4

Prepared hole

Connection position

of branch duct
(square-shaped type)

Connection position

of branch duct

(round shape type)

Connection position

of fresh air intake kit

(direct installation type)

ø100

(knock

  hole)

arrow view

C

2x100=200

160

C/L

350

124

95

109

80

90

183

25

90

157

80

213

124

[FCQN71KVEA]

C/L

160

167

67
95
29

93

90

196

80

80

160

25

90

213

157

350

20-M4

Prepared hole

Connection position

of branch duct

(square-shaped type)

Connection position

of branch duct

(round shape type)

Connection position

of fresh air intake kit
(direct installation type)

ø100

(knock

  hole)

arrow view

C

2   100

=200

[FCQN100-140KVEA]

1500 or more

(required space)

From the floor side 2500 or more

For height installation

50

64

160

256

157
350

130

95

60

105

150

42

93

67

29

160

167

840

55

55

81

85

Connection position

of branch duct

(square-shaped type)

Connection position

of branch duct

(round shape type)

27-M4 Prepared hole

35 or less

35 or less 

(Note 4)

(Note 4)

3

5

A

2   100=200

[FCQN71KVEA]

[FCQN71KVEA]

[FCQN100-140KVEA]

[FCQN71-140KVEA]

[FCQN71-140KVEA]

[FCQN100-140KVEA]

2   100=200

160

C/L

160

157
350

81

85

67

167

95

29

93

Connection position

of branch duct
(round shape type)

Connection position

of branch duct

(square-shaped type)

16-M4 Hole

arrow view

B

[FCQN100-140KVEA]

Adjustable(0~675)

Connection position

of branch duct

(square-shaped type)

16-M4 Prepared hole

(round shape type)

Connection position

of branch duct

Suspension bolt
4-M8~M10

1

160

850

280

80

10

330

340

50

55

4

55

40

80

125

29

95

157

298

167

160

350

175

165

288

20

2   100=200

2

840

160

C/L

14

Summary of Contents for SkyAirFCQN-KVEA

Page 1: ...PCSAU0739C HEAT PUMP 50Hz Air Conditioning Systems FCQN KVEA RQ LV1A 360 airflow 360 airflow...

Page 2: ...nd Flow CEILING MOUNTED CASSETTE TYPE OUTDOOR UNIT INDOOR UNIT Series PRODUCT RANGE Round Flow FCQN71KVEA 71 FCQN100KVEA FCQN125KVEA FCQN140KVEA 100 125 140 RQ71LV1A RQ100LV1A RQ125LV1A RQ140LV1A NEW...

Page 3: ...sy to clean Non flocking horizontal louvres Bactericidal treatment for drain pan Helps prevents mould and microorganisms growing out of the dust and moisture that adheres to the filters Filter has ant...

Page 4: ...ings that must be kept spotless Standard setting to prevent draft Standard setting Setting to prevent soiling of ceiling At heating startup and thermo OFF air discharge is automatically set to a near...

Page 5: ...direct connection round duct Outside Note Use of options will increase operating sound The units can be installed in the following different ways Note Some ceiling constructions may hinder installati...

Page 6: ...moved or layout modified Facilitates pump down Refrigerant recovery function Pump down function is available for pre charged refrigerant amount 20 10 0 10 20 30 40 50 Wide operation range 46 CDB Cooli...

Page 7: ...n expanded gas resulting high efficiency compression Night time quiet operation function The Automatic night quiet mode will initiate 8 hours after the peak temperature is reached in the daytime and n...

Page 8: ...arious icons and texts to be displayed smoothly Large text display improves readability Equipped backlight helps operating in dark rooms Dot matrix display Backlight display Available in 10 languages...

Page 9: ...type The wireless remote controller is supplied in a set with a signal receiver Signal receiver unit is contained inside decoration panel or indoor unit Shape of signal receiver unit differs according...

Page 10: ...receiver unit installed on indoor unit HeatReclaimVentilatorforindoorunitswithinazoneareoperatedby interlocking Canalsobeoperatedindependentlybyremotecontroller Central remote controller option Heat...

Page 11: ...ontroller Swing pattern selection Delivers air conditioning comfort all the way down to the floor in air conditioning zones with high ceilings High ceiling application Draft prevention function heatin...

Page 12: ...iping If the refrigerant piping length does not exceed 30 m there is no need for on site gas charging Drain pump mechanism Pre charged for up to 30 metres The filter sign warns you when it is time to...

Page 13: ...5 5 Hermetically sealed scroll type o 26 0 Hole 2 4 3 7 Charged for 30 m I Do 25XO Do 32 33 22 5 12 5 6 3 12 5 14 0 7 0 14 0 FCQN140KVEA RQ140LV1A o 9 5 o 15 9 52 54 dB A Night quiet mode 45 46 46 47...

Page 14: ...the same side to which a fresh air intake kit direct mount is installed Panel grille related Independently installable optional parts Operation control related Auxillary function related Filter relat...

Page 15: ...been damp and troubled under an indoor unit When the case where humidity is 80 or more and the drain outlet are choked up and the air filter are dirty dew may fall 1500 or more required space From the...

Page 16: ...ply wiring intake Control wiring intake Drain outlet 1 2 3 4 5 6 7 8 OUTDOOR UNIT RQ100LV1A 125LV1A 140LV1A OUTDOOR UNIT RQ71LV1A Gas pipe connection Liquid pipe connection Service port Grounding term...

Page 17: ...00 m Type Vinyl cord with sheath or cable insulated thickness 1mm or more Through hole 8 10 Condit Lower case portion Switch box for one switch ex KJB111A optional accessory Switch box for two switch...

Page 18: ...than two units 100 or more 500 or less 1000 or more An obstruction in the overhead space 500 or less 500 or more 1000 or more An obstruction in the overhead space 150 or more 150 or more 150 or more 5...

Page 19: ...MEMO 18...

Page 20: ...subsidiaries in Japan are certified under the ISO 14001 international standard for environment management Warning Daikin products are manufactured for export to numerous countries throughout the worl...