background image

Airflow 

distribution

creates uniform 

comfort throughout 

the space

Comfort enhanced by Round Flow!

With uniform temperature 
distribution

Enhanced Comfort

Greater comfort

• Condition after exposure 

to the smoke of 600 
cigarettes in 1 m

3

 

enclosed space.

Treated 

surface

Untreated 

surface

Grimy 

surface

Resists 

soiling

External panels are treated with a coating that helps to 
repel dirt.

Anti bacterial treatment, that includes 
silver ions is used which may assist in 
preventing the growth of microorganisms 
that cause smells and clogging.

Avoids uneven temperature and discomfort caused by drafts.

To prevent dirt sticking to the 
external panels, they have 
been coated with a surface 
treatment.

As air flows out from corner outlets, comfort spreads more evenly.

360

°

 airflow

Air movement is gentle 

with Round Flow

Dew does not easily form on the non-
flocking louvres and may prevent dirt 
from clinging  to them. It is easy to 
clean.

Non-flocking horizontal louvres

Bactericidal treatment for 
drain pan

Helps prevents mould and 
microorganisms growing out of the dust 
and moisture 
that adheres to the filters.

Filter has anti-mould and 
bactericidal treatment

Grime prevention and bactericidal coating: Makes cleaning easier.

Adapts easily to the installation space.

3-way flow

L-shaped 

2-way flow

Opposite 

2-way flow

(E.g., installed in 

a corner)

(E.g., installed in 

a long room)

(E.g., installed 

near a wall)

(E.g., installed in 

middle of ceiling)

4-way flow also possible.

All-round flow

360

°

 airflow can 

maintain comfort 
even if air 
discharge speed is 
lower.

Typical flow patterns

There are a total of 23 flow patterns. 

Note: Whatever the discharge direction, the same type of panel is used. If  installing for other than all-round flow, an air discharge outlet sealing member (option) must be used to 

close each unused outlet.

Operation sound  increases when using 2-way or 3-way flow.

2

If you raise the set 
temperature by 1 to      
1.5     in cooling (and 
lower in heating),
and velocity is decreased 
by 25%, you still obtain 
the same feeling 
temperature and comfort.

Summary of Contents for SkyAirFCQN-KVEA

Page 1: ...PCSAU0739C HEAT PUMP 50Hz Air Conditioning Systems FCQN KVEA RQ LV1A 360 airflow 360 airflow...

Page 2: ...nd Flow CEILING MOUNTED CASSETTE TYPE OUTDOOR UNIT INDOOR UNIT Series PRODUCT RANGE Round Flow FCQN71KVEA 71 FCQN100KVEA FCQN125KVEA FCQN140KVEA 100 125 140 RQ71LV1A RQ100LV1A RQ125LV1A RQ140LV1A NEW...

Page 3: ...sy to clean Non flocking horizontal louvres Bactericidal treatment for drain pan Helps prevents mould and microorganisms growing out of the dust and moisture that adheres to the filters Filter has ant...

Page 4: ...ings that must be kept spotless Standard setting to prevent draft Standard setting Setting to prevent soiling of ceiling At heating startup and thermo OFF air discharge is automatically set to a near...

Page 5: ...direct connection round duct Outside Note Use of options will increase operating sound The units can be installed in the following different ways Note Some ceiling constructions may hinder installati...

Page 6: ...moved or layout modified Facilitates pump down Refrigerant recovery function Pump down function is available for pre charged refrigerant amount 20 10 0 10 20 30 40 50 Wide operation range 46 CDB Cooli...

Page 7: ...n expanded gas resulting high efficiency compression Night time quiet operation function The Automatic night quiet mode will initiate 8 hours after the peak temperature is reached in the daytime and n...

Page 8: ...arious icons and texts to be displayed smoothly Large text display improves readability Equipped backlight helps operating in dark rooms Dot matrix display Backlight display Available in 10 languages...

Page 9: ...type The wireless remote controller is supplied in a set with a signal receiver Signal receiver unit is contained inside decoration panel or indoor unit Shape of signal receiver unit differs according...

Page 10: ...receiver unit installed on indoor unit HeatReclaimVentilatorforindoorunitswithinazoneareoperatedby interlocking Canalsobeoperatedindependentlybyremotecontroller Central remote controller option Heat...

Page 11: ...ontroller Swing pattern selection Delivers air conditioning comfort all the way down to the floor in air conditioning zones with high ceilings High ceiling application Draft prevention function heatin...

Page 12: ...iping If the refrigerant piping length does not exceed 30 m there is no need for on site gas charging Drain pump mechanism Pre charged for up to 30 metres The filter sign warns you when it is time to...

Page 13: ...5 5 Hermetically sealed scroll type o 26 0 Hole 2 4 3 7 Charged for 30 m I Do 25XO Do 32 33 22 5 12 5 6 3 12 5 14 0 7 0 14 0 FCQN140KVEA RQ140LV1A o 9 5 o 15 9 52 54 dB A Night quiet mode 45 46 46 47...

Page 14: ...the same side to which a fresh air intake kit direct mount is installed Panel grille related Independently installable optional parts Operation control related Auxillary function related Filter relat...

Page 15: ...been damp and troubled under an indoor unit When the case where humidity is 80 or more and the drain outlet are choked up and the air filter are dirty dew may fall 1500 or more required space From the...

Page 16: ...ply wiring intake Control wiring intake Drain outlet 1 2 3 4 5 6 7 8 OUTDOOR UNIT RQ100LV1A 125LV1A 140LV1A OUTDOOR UNIT RQ71LV1A Gas pipe connection Liquid pipe connection Service port Grounding term...

Page 17: ...00 m Type Vinyl cord with sheath or cable insulated thickness 1mm or more Through hole 8 10 Condit Lower case portion Switch box for one switch ex KJB111A optional accessory Switch box for two switch...

Page 18: ...than two units 100 or more 500 or less 1000 or more An obstruction in the overhead space 500 or less 500 or more 1000 or more An obstruction in the overhead space 150 or more 150 or more 150 or more 5...

Page 19: ...MEMO 18...

Page 20: ...subsidiaries in Japan are certified under the ISO 14001 international standard for environment management Warning Daikin products are manufactured for export to numerous countries throughout the worl...