If there is a malfunction elsewhere in the system, the fan or 
compressor can still be operated.

Insufficient gas charging is normally hard to detect. During 
post-installation trials and regular inspection procedures, the 
refrigerant level is monitored by a microprocessor to maintain 
proper gas pressure. Reliability is assured and maintenance 
and inspection can be carried out more quickly.

You can turn up to 16 indoor units on/off with a single remote 
controller. (When using connected indoor units, the settings 
must all be the same and on/off will be simultaneous.)

Emergency operation

Low gas pressure detection

Group control by 1 remote controller

Operation and surveillance is carried out using the contact 
signal from the operation control box in the building 
surveillance (security) room.

External command control

An optional central remote controller enables centralised 
control of up to 1024 indoor units (64 groups) from up to 1 
kilometer away.

Central remote control

Enables interlocking control with external equipment such as 
Heat Reclaim Ventilator.

Interlock control

The operating parameters of indoor and outdoor units, and 
sensor data at critical locations throughout the system, are 
constantly monitored using a microcomputer. To facilitate a 
quick response in the event of a malfunction, a message 
appears on the LCD of the remote controller and an LED on 
the unit illuminates.

Self diagnosis function

Two types are available: 65% and 90% colorimetry. 

High-efficiency filter unit

You can provide air-conditioning with fresh air from outside. 
Convenient for places where a ventilation fan cannot be 
installed. 

Fresh-air intake kit

Work and Servicing

Control features

Options

Steeper gradient realises more 
efficient condensate drainage. 
High-lift is especially useful for 
long lengths of drain piping.

If the refrigerant piping length does not exceed 30 m, there is 
no need for on-site gas charging.

Drain pump mechanism

Pre charged for up to 30 metres

The filter sign warns you when it is time to clean the filter. 

*When using a wired remote controller the sign is displayed in the LCD. When using a 
wireless remote controller the filter sign lamp illuminates on the signal receiver unit.

Filter sign

Daikin's innovative air discharge mechanism keeps airflow 
away from the ceiling. Ceiling cleaning is less frequently 
required.

Ceiling soiling prevention function

If there is a power outage while the equipment is operating, 
operations will restart in the same mode as before the power 
cut when electricity is restored.

Using 2 remote controllers you can operate the equipment 
locally or from a remote location.

Note: When a wireless remote controller is used, remote control by two remote controllers is 
not possible.

Auto-restart

Control by 2 remote controllers

Detects difference in preset temperature and actual room 
temperature and automatically switches to cooling or heating 
accordingly.

Auto cool/heat change-over 

(Heat pump only)

*Required for KRP58M51 (Option)

*Connecting ducts, insect nets, fire dampers, air filters, and other parts 

should, as required, be procured locally. 

**Outside Air fan interlocked with air conditioning unit is necessary. Optional 

PCB(KRP1C63)is required for interlocking.

***It is recommended that the volume of outdoor air introduced through the kit 

is limited to 10% of the maximum airflow rate of the indoor unit. Introducing 
higher quantities will increase the operating noise and may also influence 
temperature sending. 

Note: 

To achieve increased durability by improved resistance to salt corrosion and atmospheric pollution, coated Anti corrosion treated heat 
exchangers (with special acryl pretreatment) are used for the heat exchanger of the outdoor unit.
In high corrosive areas, regular maintenance needs to be carried out.

Anti corrosion treated heat exchangers

O t h e r s

11

Summary of Contents for SkyAirFCQN-KVEA

Page 1: ...PCSAU0739C HEAT PUMP 50Hz Air Conditioning Systems FCQN KVEA RQ LV1A 360 airflow 360 airflow...

Page 2: ...nd Flow CEILING MOUNTED CASSETTE TYPE OUTDOOR UNIT INDOOR UNIT Series PRODUCT RANGE Round Flow FCQN71KVEA 71 FCQN100KVEA FCQN125KVEA FCQN140KVEA 100 125 140 RQ71LV1A RQ100LV1A RQ125LV1A RQ140LV1A NEW...

Page 3: ...sy to clean Non flocking horizontal louvres Bactericidal treatment for drain pan Helps prevents mould and microorganisms growing out of the dust and moisture that adheres to the filters Filter has ant...

Page 4: ...ings that must be kept spotless Standard setting to prevent draft Standard setting Setting to prevent soiling of ceiling At heating startup and thermo OFF air discharge is automatically set to a near...

Page 5: ...direct connection round duct Outside Note Use of options will increase operating sound The units can be installed in the following different ways Note Some ceiling constructions may hinder installati...

Page 6: ...moved or layout modified Facilitates pump down Refrigerant recovery function Pump down function is available for pre charged refrigerant amount 20 10 0 10 20 30 40 50 Wide operation range 46 CDB Cooli...

Page 7: ...n expanded gas resulting high efficiency compression Night time quiet operation function The Automatic night quiet mode will initiate 8 hours after the peak temperature is reached in the daytime and n...

Page 8: ...arious icons and texts to be displayed smoothly Large text display improves readability Equipped backlight helps operating in dark rooms Dot matrix display Backlight display Available in 10 languages...

Page 9: ...type The wireless remote controller is supplied in a set with a signal receiver Signal receiver unit is contained inside decoration panel or indoor unit Shape of signal receiver unit differs according...

Page 10: ...receiver unit installed on indoor unit HeatReclaimVentilatorforindoorunitswithinazoneareoperatedby interlocking Canalsobeoperatedindependentlybyremotecontroller Central remote controller option Heat...

Page 11: ...ontroller Swing pattern selection Delivers air conditioning comfort all the way down to the floor in air conditioning zones with high ceilings High ceiling application Draft prevention function heatin...

Page 12: ...iping If the refrigerant piping length does not exceed 30 m there is no need for on site gas charging Drain pump mechanism Pre charged for up to 30 metres The filter sign warns you when it is time to...

Page 13: ...5 5 Hermetically sealed scroll type o 26 0 Hole 2 4 3 7 Charged for 30 m I Do 25XO Do 32 33 22 5 12 5 6 3 12 5 14 0 7 0 14 0 FCQN140KVEA RQ140LV1A o 9 5 o 15 9 52 54 dB A Night quiet mode 45 46 46 47...

Page 14: ...the same side to which a fresh air intake kit direct mount is installed Panel grille related Independently installable optional parts Operation control related Auxillary function related Filter relat...

Page 15: ...been damp and troubled under an indoor unit When the case where humidity is 80 or more and the drain outlet are choked up and the air filter are dirty dew may fall 1500 or more required space From the...

Page 16: ...ply wiring intake Control wiring intake Drain outlet 1 2 3 4 5 6 7 8 OUTDOOR UNIT RQ100LV1A 125LV1A 140LV1A OUTDOOR UNIT RQ71LV1A Gas pipe connection Liquid pipe connection Service port Grounding term...

Page 17: ...00 m Type Vinyl cord with sheath or cable insulated thickness 1mm or more Through hole 8 10 Condit Lower case portion Switch box for one switch ex KJB111A optional accessory Switch box for two switch...

Page 18: ...than two units 100 or more 500 or less 1000 or more An obstruction in the overhead space 500 or less 500 or more 1000 or more An obstruction in the overhead space 150 or more 150 or more 150 or more 5...

Page 19: ...MEMO 18...

Page 20: ...subsidiaries in Japan are certified under the ISO 14001 international standard for environment management Warning Daikin products are manufactured for export to numerous countries throughout the worl...

Reviews: