Use the temperature-sensor in the 
indoor unit when controlling air 
conditioning from another room.

Temperature-sensors are included in the indoor unit and 
optional wired remote controller.  Temperature sensing closer 
to the target area is possible to 
further increase the comfort 
level.

Note: Wireless remote controllers have no 

temperature-sensor.

Abundance of features that provide comfortable 
air-conditioning in stores and offices.

The air flow direction can be fixed
at your desited angle by the 
remote controller.

Dehumidification is a microprocessor controlled to prevent 
abrupt and uncomfortable changes in air temperature. Useful 
for reducing uncomfortable humidity without uncomfortable 
cooling of the room.

Delivers comfortable air-
conditioning to all areas, 
near to and far from the air-
conditioner.

High setting provides maximum reach while low setting 
minimises drafts.

Auto-swing

Programme "Dry" with a humidity sensor

Switchable fan speed

(1) Air direction in 

standard setting

(2) Air direction in ceiling

soiling prevention 
setting

(standard, ceiling soiling prevention)

Note:When units are installed on high ceilings, depending on the model, 

various restrictions concerning maximum height, air discharge direction, 
and choice of options may apply.

You can freely set 2 air discharge settings by remote controller.

Swing pattern selection

Delivers air-conditioning comfort all the way down to the floor 
in air-conditioning zones with high ceilings.

High-ceiling application

Draft prevention function

 (heating)

Efficient cooling even in winter when the indoor temperatures 
are higher than those outside, such as in underground public 
spaces or offices with many computers.

Year-round cooling applicable

Operation starts when the preset time of the ON timer elapses 
and stops when the preset time of the OFF timer elapses.

Timer selector

Up to five operation ON/OFF settings can be programmed per 
day for each day of the week. Not only can the time be set for 
the operation ON setting, but also the temperature.

Weekly schedule timer

Cold air flow is avoided when heating operation starts or 
when switching to heat after defrosting.

Hot start 

(after defrost)

Two selectable temperature-sensors

Drain pan has silver ion anti-bacterial treatment to help 
prevent the growth of bacteria and mould.

Silver ion anti-bacterial drain pan

The Air filter has a anti-bacterial treatment to help prevent 
the growth of bacteria and mould on it.

Anti-bacterial air filter

C o m f o r t

Cleanliness

To prevent cold air drafts, automatically adjusts airflow to near 
horizontal position when heating initially starts or when the 
thermostat turns off.

The Automatic night quiet mode will initiate 8 hours after the 
peak temperature is reached in the daytime, and normal 
operation will resume 10 hours after that. 

Night quiet operation

10

Summary of Contents for SkyAirFCQN-KVEA

Page 1: ...PCSAU0739C HEAT PUMP 50Hz Air Conditioning Systems FCQN KVEA RQ LV1A 360 airflow 360 airflow...

Page 2: ...nd Flow CEILING MOUNTED CASSETTE TYPE OUTDOOR UNIT INDOOR UNIT Series PRODUCT RANGE Round Flow FCQN71KVEA 71 FCQN100KVEA FCQN125KVEA FCQN140KVEA 100 125 140 RQ71LV1A RQ100LV1A RQ125LV1A RQ140LV1A NEW...

Page 3: ...sy to clean Non flocking horizontal louvres Bactericidal treatment for drain pan Helps prevents mould and microorganisms growing out of the dust and moisture that adheres to the filters Filter has ant...

Page 4: ...ings that must be kept spotless Standard setting to prevent draft Standard setting Setting to prevent soiling of ceiling At heating startup and thermo OFF air discharge is automatically set to a near...

Page 5: ...direct connection round duct Outside Note Use of options will increase operating sound The units can be installed in the following different ways Note Some ceiling constructions may hinder installati...

Page 6: ...moved or layout modified Facilitates pump down Refrigerant recovery function Pump down function is available for pre charged refrigerant amount 20 10 0 10 20 30 40 50 Wide operation range 46 CDB Cooli...

Page 7: ...n expanded gas resulting high efficiency compression Night time quiet operation function The Automatic night quiet mode will initiate 8 hours after the peak temperature is reached in the daytime and n...

Page 8: ...arious icons and texts to be displayed smoothly Large text display improves readability Equipped backlight helps operating in dark rooms Dot matrix display Backlight display Available in 10 languages...

Page 9: ...type The wireless remote controller is supplied in a set with a signal receiver Signal receiver unit is contained inside decoration panel or indoor unit Shape of signal receiver unit differs according...

Page 10: ...receiver unit installed on indoor unit HeatReclaimVentilatorforindoorunitswithinazoneareoperatedby interlocking Canalsobeoperatedindependentlybyremotecontroller Central remote controller option Heat...

Page 11: ...ontroller Swing pattern selection Delivers air conditioning comfort all the way down to the floor in air conditioning zones with high ceilings High ceiling application Draft prevention function heatin...

Page 12: ...iping If the refrigerant piping length does not exceed 30 m there is no need for on site gas charging Drain pump mechanism Pre charged for up to 30 metres The filter sign warns you when it is time to...

Page 13: ...5 5 Hermetically sealed scroll type o 26 0 Hole 2 4 3 7 Charged for 30 m I Do 25XO Do 32 33 22 5 12 5 6 3 12 5 14 0 7 0 14 0 FCQN140KVEA RQ140LV1A o 9 5 o 15 9 52 54 dB A Night quiet mode 45 46 46 47...

Page 14: ...the same side to which a fresh air intake kit direct mount is installed Panel grille related Independently installable optional parts Operation control related Auxillary function related Filter relat...

Page 15: ...been damp and troubled under an indoor unit When the case where humidity is 80 or more and the drain outlet are choked up and the air filter are dirty dew may fall 1500 or more required space From the...

Page 16: ...ply wiring intake Control wiring intake Drain outlet 1 2 3 4 5 6 7 8 OUTDOOR UNIT RQ100LV1A 125LV1A 140LV1A OUTDOOR UNIT RQ71LV1A Gas pipe connection Liquid pipe connection Service port Grounding term...

Page 17: ...00 m Type Vinyl cord with sheath or cable insulated thickness 1mm or more Through hole 8 10 Condit Lower case portion Switch box for one switch ex KJB111A optional accessory Switch box for two switch...

Page 18: ...than two units 100 or more 500 or less 1000 or more An obstruction in the overhead space 500 or less 500 or more 1000 or more An obstruction in the overhead space 150 or more 150 or more 150 or more 5...

Page 19: ...MEMO 18...

Page 20: ...subsidiaries in Japan are certified under the ISO 14001 international standard for environment management Warning Daikin products are manufactured for export to numerous countries throughout the worl...

Reviews: