Turn on the main power supply switch

The display on the remote controller will be 

• 

shown when the power is turned on.
To protect the unit, turn on the main power 

• 

switch at least 6 hours before operation.

WHAT TO DO WHEN STOPPING THE 
SYSTEM FOR A LONG PERIOD

Turn on FAN OPERATION for a half day and dry 
the unit.

Read the operation manual that came with the 

• 

remote controller.

Cut off the power supply.

When the main power switch is turned on, some 

• 

watts of electricity is being used even if the sys-
tem is not operating.
Turn off the main power supply switch for saving 
energy.
The display on the remote controller will vanish 

• 

when the main power switch is turned off. 

Clean the air fi lter and the exterior.

Be sure to replace the air fi lter to its original 

• 

place after cleaning. Refer to “MAINTENANCE”.

NOT MALFUNCTION OF THE AIR 

9. 

CONDITIONER

The following symptoms do not indicate air condi-
tioner malfunction

THE SYSTEM DOES NOT OPERATE

I. 

The system does not restart immediately 

• 

after the ON/OFF button is pressed.

If the OPERATION lamp lights, the system is in 
normal condition.
It does not restart immediately because a 
safety device operates to prevent overload of 
the system. After 3 minutes, the system will 
turn on again automatically.

The system does not restart immediately 

• 

when TEMPERATURE SETTING button is 
returned to the former position after push-
ing the button.

If the OPERATION lamp lights, the system is in 
normal condition.
It does not restart immediately because a 
safety device operates to prevent overload of 
the system. After 3 minutes, the system will 
turn on again automatically.

The system does not start when the display 

• 

shows “ 

 ” and it fl ashes for few 

seconds after pressing an operation button.

This is because the system is under central-
ized control. Flashes on the display indicates 
that the system cannot be controlled by the 
remote controller.

The system does not start immediately 

• 

after the power supply is turned on.

Wait one minute until the micro computer is 
prepared for operation.

The fan speed is different from the setting.

II. 

Pressing the fan speed control button does 

• 

not change the fan speed.

When the room temperature reaches the set 
temperature in heating mode, the outdoor unit 
stops and the indoor unit switches to whisper 
mode. This is to prevent the cool air from being 
blown directly onto anyone in the room.

AIR BLOW DIRECTION IS NOT AS SPECI-

III. 

FIED.

Actual air blow direction is not as shown on 

• 

the remote controller.

Automatic swing setting does not work.

• 

Refer to “AIR FLOW DIRECTION ADJUST.”

WHITE MIST COMES OUT OF A UNIT

IV. 

When humidity is high during cooling op-

• 

eration (In oily or dusty places)

If the inside of an indoor unit is extremely con-
taminated, the temperature distribution inside a 
room becomes uneven. It is necessary to clean 
the inside of the indoor unit. Ask your Daikin 
dealer for details on cleaning the unit. This 
operation requires a qualifi ed service person.

When the system is changed over to HEAT-

• 

ING OPERATION after DEFROST OPERA-
TION.

Moisture generated by DEFROST becomes 
steam and exists.

NOISE OF AIR CONDITIONERS

V. 

A ringing sound after the unit is started.

• 

This sound is generated by the temperature 
regulator working.
It will quiet down after about a minute.

A continuous fl ow “Shuh” sound is heard 

• 

when the systems is in COOLING or DE-
FROST OPERATION.

This is the sound of refrigerant gas fl owing 
through both indoor and outdoor units.

01_EN_3PN07520-2A.indd   11

01_EN_3PN07520-2A.indd   11

12/24/2008   2:47:05 PM

12/24/2008   2:47:05 PM

Summary of Contents for SkyAir FAQ18PVJU

Page 1: ...nce This manual should be left with the equipment owner Lire soigneusement ces instructions avant l installation Conserver ce manuel port e de main pour r f rence ult rieure Ce manuel doit tre donn au...

Page 2: ...1 2 9 10 3 1 4 5 6 7 13 14 15 16 17 18 19 20 21 11 8 12 1 b d f k e i h a j d f g e c 3 2 4...

Page 3: ...ntrollers control one indoor unit The unit is individually operated NOTE Contact your dealer in case of two remote con trollers control system Names and functions of parts Refer to figure 2 on page 1...

Page 4: ...sufficiently to avoid this hazard Safely dispose of the packing materials Packing materials such as nails and other metal or wooden parts may cause stabs or other inju ries Tear apart and throw away p...

Page 5: ...above 80 or if the drain outlet gets blocked Avoid placing the controller in a spot splashed with water Water coming inside the unit may cause an elec tric leak or may damage the internal electronic...

Page 6: ...is much salt such as a beach area c Where sulfured gas exists such as a hot spring resort d Where there are considerable voltage fluctua tions such as a factory or plant e Vehicles and vessels f Where...

Page 7: ...AIR FLOW DIRECTION ADJUST 10 DISPLAY TIME TO CLEAN AIR FIL TER Refer to HOW TO CLEAN THE AIR FILTER 11 DISPLAY DEFROST Refer to DEFROST OPERATION 12 NON FUNCTIONING DISPLAY If that particular function...

Page 8: ...irection to the right and left Air outlet 10 AIR FLOW DIRECTION ADJUST There are 2 ways of adjusting the air discharge angle A Up and down direction B Left and right direction A UP AND DOWN DIRECTION...

Page 9: ...is swinging COOLING HEATING AUTOMATIC FAN AND PROGRAM DRY OPERATION Operate in the following order 1 OPERATION MODE SELECTOR Press OPERATION MODE SELECTOR button several times and select the OPERATIO...

Page 10: ...n operation NOTE The setting temperature range of the remote controller is 60 F to 90 F FAN SPEED CONTROL Press FAN SPEED CONTROL button High or Low fan speed can be selected The microchip may sometim...

Page 11: ...me watts of elec tricity is being used even if the system is not operating Turn off the main power supply switch for saving energy When reoperating turn on the main power supply switch 6 hours before...

Page 12: ...ine thinner or other volatile substances polishing powder or hard scrub brushes to clean the pan el Make sure the front panel is solidly in place Open the front panel 1 Place your fingers on the protr...

Page 13: ...The system does not start when the display shows and it flashes for few seconds after pressing an operation button This is because the system is under central ized control Flashes on the display indic...

Page 14: ...the air conditioner is in abnormal con ditions smell of something burning etc unplug the power cord from the outlet and contact your dealer Continued operation under such circumstances may result in a...

Page 15: ...lated If the air filter is clogged Ask a qualified service person to clean the air filters Refer to MAINTENANCE If the set temperature is not proper Refer to ADJUSTMENT If the FAN SPEED button is set...

Page 16: ...3PN07520 2A EM08A090 0902 HT...

Reviews: