background image

English

Cut off all electric waves before maintenance.

• 

To avoid the risk of serious electrical shock, 

• 

never aprinkle or spill water or liquids on the 
unit.

Operating the air conditioner with wet hands 

• 

could result in a shock hazard.

Do not allow children to play on or around 

• 

the unit as they could be injured.

Check the unit stand for damage on a con-

• 

tinuous basis. 

If left in a damaged condition the unit may fall 
and cause injury.

Placing a fl ower vase or other containers 

• 

with water or other liquids on the unit could 
result in a shock hazard or fi re if a spill oc-
curs.

The heat exchanger fi ns are sharp enough to 

• 

cut. 

To avoid injury wear gloves or cover the fi ns 
while working around them.

Do not put a fi nger or other objects into the 

• 

air inlet or air outlet. 

The fan is rotating at high speed and will cause 
injury.

Do not touch the air outlet or the horizontal 

• 

fl aps while the swing fl ap is in operation as 
fi ngers may get caught and injured.

Be sure to install an earth leakage breaker.

• 

Failure to install an earth leakage breaker may 
result in electric shocks, or fi re.

Never touch the internal parts of the control-

• 

ler.

Do not remove the front panel because some 
parts inside are dangerous to touch. In addition, 
some parts may be damaged. For checking and 
adjusting internal parts, contact your dealer.

 CAUTION

Do not use the air conditioner for other pur-

• 

poses.

In order to avoid any quality deterioration, do not 
use the unit for cooling precision instruments, 
food, plants, animals or works of art.

Do not place items under the indoor unit 

• 

which may be damaged by water.

Condensation may form if the humidity is above 
80% or if the drain outlet gets blocked.

Avoid placing the controller in a spot 

• 

splashed with water.

Water coming inside the unit may cause an elec-
tric leak or may damage the internal electronic 
parts.

Do not operate the air conditioner when us-

• 

ing a room fumigation - type insecticide.

Failure to observe could cause the chemicals to 
become deposited in the unit, which could en-
danger the health of those who are hypersensi-
tive to chemicals.

Do not turn off the power immediately after 

• 

stopping operation.

Always wait at least fi ve minutes before turning 
off the power. Otherwise, water leakage and 
trouble may occur.

The appliance is not intended for use by 

• 

young children or infi rm persons without 
supervision.

The remote controller should be installed in 

• 

such away that children cannot play with it.

Consult with installation contractor for clean-

• 

ing the inside of the air conditioner.

Wrong cleaning may make the plastics parts 
broken or cause failure of water leakage or elec-
tric shock.

Do not touch the air inlet or aluminium fi n of 

• 

the air conditioner.

Otherwise, injury may be caused.

Do not place objects in direct proximity of 

• 

the outdoor unit and do not let leaves and 
other debris accumulate around the unit.

Leaves are a hotbed for small animals which can 
enter the unit. Once in the unit, such animals can 
cause malfunctions, smoke or fi re when making 
contact with electrical parts.

 NOTE

Never press the button of the remote control-

• 

ler with a hard, pointed object.

The remote controller may be damaged.

Never pull or twist the electric wire of the 

• 

remote controller.

It may cause the unit to malfunction.

Do not place appliances which produce open 

• 

fi re in places exposed to the air fl ow from the 
unit or under the indoor unit. It may cause 
incomplete combustion or deformation of the 
unit due to the heat.

01_EN_3PN07520-2A.indd   3

01_EN_3PN07520-2A.indd   3

12/24/2008   2:47:01 PM

12/24/2008   2:47:01 PM

Summary of Contents for SkyAir FAQ18PVJU

Page 1: ...nce This manual should be left with the equipment owner Lire soigneusement ces instructions avant l installation Conserver ce manuel port e de main pour r f rence ult rieure Ce manuel doit tre donn au...

Page 2: ...1 2 9 10 3 1 4 5 6 7 13 14 15 16 17 18 19 20 21 11 8 12 1 b d f k e i h a j d f g e c 3 2 4...

Page 3: ...ntrollers control one indoor unit The unit is individually operated NOTE Contact your dealer in case of two remote con trollers control system Names and functions of parts Refer to figure 2 on page 1...

Page 4: ...sufficiently to avoid this hazard Safely dispose of the packing materials Packing materials such as nails and other metal or wooden parts may cause stabs or other inju ries Tear apart and throw away p...

Page 5: ...above 80 or if the drain outlet gets blocked Avoid placing the controller in a spot splashed with water Water coming inside the unit may cause an elec tric leak or may damage the internal electronic...

Page 6: ...is much salt such as a beach area c Where sulfured gas exists such as a hot spring resort d Where there are considerable voltage fluctua tions such as a factory or plant e Vehicles and vessels f Where...

Page 7: ...AIR FLOW DIRECTION ADJUST 10 DISPLAY TIME TO CLEAN AIR FIL TER Refer to HOW TO CLEAN THE AIR FILTER 11 DISPLAY DEFROST Refer to DEFROST OPERATION 12 NON FUNCTIONING DISPLAY If that particular function...

Page 8: ...irection to the right and left Air outlet 10 AIR FLOW DIRECTION ADJUST There are 2 ways of adjusting the air discharge angle A Up and down direction B Left and right direction A UP AND DOWN DIRECTION...

Page 9: ...is swinging COOLING HEATING AUTOMATIC FAN AND PROGRAM DRY OPERATION Operate in the following order 1 OPERATION MODE SELECTOR Press OPERATION MODE SELECTOR button several times and select the OPERATIO...

Page 10: ...n operation NOTE The setting temperature range of the remote controller is 60 F to 90 F FAN SPEED CONTROL Press FAN SPEED CONTROL button High or Low fan speed can be selected The microchip may sometim...

Page 11: ...me watts of elec tricity is being used even if the system is not operating Turn off the main power supply switch for saving energy When reoperating turn on the main power supply switch 6 hours before...

Page 12: ...ine thinner or other volatile substances polishing powder or hard scrub brushes to clean the pan el Make sure the front panel is solidly in place Open the front panel 1 Place your fingers on the protr...

Page 13: ...The system does not start when the display shows and it flashes for few seconds after pressing an operation button This is because the system is under central ized control Flashes on the display indic...

Page 14: ...the air conditioner is in abnormal con ditions smell of something burning etc unplug the power cord from the outlet and contact your dealer Continued operation under such circumstances may result in a...

Page 15: ...lated If the air filter is clogged Ask a qualified service person to clean the air filters Refer to MAINTENANCE If the set temperature is not proper Refer to ADJUSTMENT If the FAN SPEED button is set...

Page 16: ...3PN07520 2A EM08A090 0902 HT...