background image

English

NOTE 

If you try cooling or programmed drying, while 

• 

the fl aps are facing downward, air fl ow direction 
may change unexpectedly. There is nothing 
wrong with the equipment. This serves to prevent 
dew formed on parts in the air discharge outlet 
from dripping.
Operation mode includes automatic operation.

• 

Recommended fl ap positions

Cooling

Heating

We recommend using the fan in the position listed 
above when fi xing the fan direction.

B. LEFT AND RIGHT DIRECTION

Hold the tabs on edge louvers (horizontal fan direc-
tion adjustment fl aps) down slightly and adjust left 
and right to match the room conditions or your 
preference.

Stop the horizontal fl aps at a position where you 
can hold the tabs and adjust it left and right.

NOTE 

Only make adjustments after you have stopped 

• 

the air fl ow direction swing in a position where 
adjustments are possible. Your hand may get 
caught if you attempt to make adjustments while 
the unit is swinging.

COOLING, HEATING, AUTOMATIC, FAN, 
AND PROGRAM DRY OPERATION

Operate in the following order.

1

OPERATION MODE 
SELECTOR

Press OPERATION MODE SELECTOR 
button several times and select the 
OPERATION MODE of your choice as 
follows.

COOLING OPERATION

 

„

 ...............................“   ”

HEATING OPERATION

 

„

.................................“   ”

AUTOMATIC OPERATION

 

„

 ............................“ 

 ”

In this operation mode, COOL/HEAT change-

• 

over is automatically conducted.

FAN OPERATION

 

„

 .........................................“ 

 ”

DRY OPERATION

 

„

 .........................................“ 

 ”

The function of this program is to decrease the 

• 

humidity in your room with the minimum tem-
perature decrease.
Micro computer automatically determines 

• 

TEMPERATURE and FAN SPEED.
This system does not go into operation if the 

• 

room temperature is below 60°F.

Refer to fi gure 3 on page [1]

2

ON/OFF

Press ON/OFF button.

OPERATION lamp lights up or goes off and the 
system starts or stops OPERATION.

[EXPLANATION OF HEATING OPERATION]

DEFROST OPERATION

As the frost on the coil of an outdoor unit in-

• 

crease, heating effect decreases and the system 
goes into DEFROST OPERATION.
The indoor unit fan stops and the remote control-

• 

ler display shows “ 

 ”.

After 6 to 8 minutes (maximum 10 minutes) of 

• 

DEFROST OPERATION, the system returns to 
HEATING OPERATION.

01_EN_3PN07520-2A.indd   7

01_EN_3PN07520-2A.indd   7

12/24/2008   2:47:03 PM

12/24/2008   2:47:03 PM

Summary of Contents for SkyAir FAQ18PVJU

Page 1: ...nce This manual should be left with the equipment owner Lire soigneusement ces instructions avant l installation Conserver ce manuel port e de main pour r f rence ult rieure Ce manuel doit tre donn au...

Page 2: ...1 2 9 10 3 1 4 5 6 7 13 14 15 16 17 18 19 20 21 11 8 12 1 b d f k e i h a j d f g e c 3 2 4...

Page 3: ...ntrollers control one indoor unit The unit is individually operated NOTE Contact your dealer in case of two remote con trollers control system Names and functions of parts Refer to figure 2 on page 1...

Page 4: ...sufficiently to avoid this hazard Safely dispose of the packing materials Packing materials such as nails and other metal or wooden parts may cause stabs or other inju ries Tear apart and throw away p...

Page 5: ...above 80 or if the drain outlet gets blocked Avoid placing the controller in a spot splashed with water Water coming inside the unit may cause an elec tric leak or may damage the internal electronic...

Page 6: ...is much salt such as a beach area c Where sulfured gas exists such as a hot spring resort d Where there are considerable voltage fluctua tions such as a factory or plant e Vehicles and vessels f Where...

Page 7: ...AIR FLOW DIRECTION ADJUST 10 DISPLAY TIME TO CLEAN AIR FIL TER Refer to HOW TO CLEAN THE AIR FILTER 11 DISPLAY DEFROST Refer to DEFROST OPERATION 12 NON FUNCTIONING DISPLAY If that particular function...

Page 8: ...irection to the right and left Air outlet 10 AIR FLOW DIRECTION ADJUST There are 2 ways of adjusting the air discharge angle A Up and down direction B Left and right direction A UP AND DOWN DIRECTION...

Page 9: ...is swinging COOLING HEATING AUTOMATIC FAN AND PROGRAM DRY OPERATION Operate in the following order 1 OPERATION MODE SELECTOR Press OPERATION MODE SELECTOR button several times and select the OPERATIO...

Page 10: ...n operation NOTE The setting temperature range of the remote controller is 60 F to 90 F FAN SPEED CONTROL Press FAN SPEED CONTROL button High or Low fan speed can be selected The microchip may sometim...

Page 11: ...me watts of elec tricity is being used even if the system is not operating Turn off the main power supply switch for saving energy When reoperating turn on the main power supply switch 6 hours before...

Page 12: ...ine thinner or other volatile substances polishing powder or hard scrub brushes to clean the pan el Make sure the front panel is solidly in place Open the front panel 1 Place your fingers on the protr...

Page 13: ...The system does not start when the display shows and it flashes for few seconds after pressing an operation button This is because the system is under central ized control Flashes on the display indic...

Page 14: ...the air conditioner is in abnormal con ditions smell of something burning etc unplug the power cord from the outlet and contact your dealer Continued operation under such circumstances may result in a...

Page 15: ...lated If the air filter is clogged Ask a qualified service person to clean the air filters Refer to MAINTENANCE If the set temperature is not proper Refer to ADJUSTMENT If the FAN SPEED button is set...

Page 16: ...3PN07520 2A EM08A090 0902 HT...