background image

English 

8

Regarding outside air temperature and 
heating capacity

The heating capacity of the air conditioner de-

• 

clines as the outside air temperature falls. In this 
case, use the air conditioner in combination with 
other heating systems.
A warm air circulating system is employed, and 

• 

therefore it takes some time until the entire room 
is warmed up after the start of operation.
An indoor fan runs to discharge a gentle wind 

• 

automatically until the temperature inside the air 
conditioner reaches a certain level. At this time, 
the remote controller displays “ 

 ”. Leave it 

as it stands and wait for a while.
When the warm air stays under the ceiling and 

• 

your feet are cold, we recommend that you use a 
circulator (a fan to circulate the air inside the 
room). For details, consult your dealer.

ADJUSTMENT

For programming TEMPERATURE, FAN SPEED 
and AIR FLOW DIRECTION, follow the procedure 
shown below.

TEMPERATURE SETTING 

Press TEMPERATURE SETTING button and 
program the setting temperature.

Each time this button is pressed, 
setting temperature rises 1°F.

Each time this button is pressed, 
setting temperature lowers 1°F.

The setting is impossible for fan operation.

• 

 NOTE

The setting temperature range of the remote 

 

controller is 60°F to 90°F.

FAN SPEED CONTROL

Press FAN SPEED CONTROL button.

High or Low fan speed can be selected.
The microchip may sometimes control the fan 
speed in order to protect the unit.

PROGRAM TIMER  OPERATION

Operate in the following order.

The timer is operated in the following two ways.

• 

Programming the stop time  ( 

• 

 ) .... The 

system stops 
operating after the set time has elapsed.
Programming the start time ( 

• 

 ) .... The sys-

tem starts 
operating after the set time has elapsed. 
The timer can be programmed a maximum of 

• 

72 hours.
The start and the stop time can be simultane-

• 

ously programmed.

1

TIMER MODE START/STOP

Press the TIMER MODE START/STOP 
button several times and select the mode 
on the display.

The display fl ashes.
For setting the timer stop .... “ 

 ”

For setting the timer start .... “ 

 ”

2

PROGRAMMING TIME

Press the PROGRAMMING TIME button and 
set the time for stopping or starting the 
system.

When this button is pressed, the time 
advances by 1 hour.

When this button is pressed, the time 
goes backward by 1 hour.

3

TIMER ON/OFF

Press the TIMER ON/OFF button.

The timer setting procedure ends. 
The display “ 

  or  

 ” changes from fl ash-

ing light to a constant light.

Refer to fi gure 4 on page [1]

 NOTE

When setting the timer Off and On at the same 

 

time, repeat the above procedure from 

1

 to 

3

once again.

01_EN_3PN07520-2A.indd   8

01_EN_3PN07520-2A.indd   8

12/24/2008   2:47:03 PM

12/24/2008   2:47:03 PM

Summary of Contents for SkyAir FAQ18PVJU

Page 1: ...nce This manual should be left with the equipment owner Lire soigneusement ces instructions avant l installation Conserver ce manuel port e de main pour r f rence ult rieure Ce manuel doit tre donn au...

Page 2: ...1 2 9 10 3 1 4 5 6 7 13 14 15 16 17 18 19 20 21 11 8 12 1 b d f k e i h a j d f g e c 3 2 4...

Page 3: ...ntrollers control one indoor unit The unit is individually operated NOTE Contact your dealer in case of two remote con trollers control system Names and functions of parts Refer to figure 2 on page 1...

Page 4: ...sufficiently to avoid this hazard Safely dispose of the packing materials Packing materials such as nails and other metal or wooden parts may cause stabs or other inju ries Tear apart and throw away p...

Page 5: ...above 80 or if the drain outlet gets blocked Avoid placing the controller in a spot splashed with water Water coming inside the unit may cause an elec tric leak or may damage the internal electronic...

Page 6: ...is much salt such as a beach area c Where sulfured gas exists such as a hot spring resort d Where there are considerable voltage fluctua tions such as a factory or plant e Vehicles and vessels f Where...

Page 7: ...AIR FLOW DIRECTION ADJUST 10 DISPLAY TIME TO CLEAN AIR FIL TER Refer to HOW TO CLEAN THE AIR FILTER 11 DISPLAY DEFROST Refer to DEFROST OPERATION 12 NON FUNCTIONING DISPLAY If that particular function...

Page 8: ...irection to the right and left Air outlet 10 AIR FLOW DIRECTION ADJUST There are 2 ways of adjusting the air discharge angle A Up and down direction B Left and right direction A UP AND DOWN DIRECTION...

Page 9: ...is swinging COOLING HEATING AUTOMATIC FAN AND PROGRAM DRY OPERATION Operate in the following order 1 OPERATION MODE SELECTOR Press OPERATION MODE SELECTOR button several times and select the OPERATIO...

Page 10: ...n operation NOTE The setting temperature range of the remote controller is 60 F to 90 F FAN SPEED CONTROL Press FAN SPEED CONTROL button High or Low fan speed can be selected The microchip may sometim...

Page 11: ...me watts of elec tricity is being used even if the system is not operating Turn off the main power supply switch for saving energy When reoperating turn on the main power supply switch 6 hours before...

Page 12: ...ine thinner or other volatile substances polishing powder or hard scrub brushes to clean the pan el Make sure the front panel is solidly in place Open the front panel 1 Place your fingers on the protr...

Page 13: ...The system does not start when the display shows and it flashes for few seconds after pressing an operation button This is because the system is under central ized control Flashes on the display indic...

Page 14: ...the air conditioner is in abnormal con ditions smell of something burning etc unplug the power cord from the outlet and contact your dealer Continued operation under such circumstances may result in a...

Page 15: ...lated If the air filter is clogged Ask a qualified service person to clean the air filters Refer to MAINTENANCE If the set temperature is not proper Refer to ADJUSTMENT If the FAN SPEED button is set...

Page 16: ...3PN07520 2A EM08A090 0902 HT...