background image

English 

4

Arrange the drain hose to ensure smooth 

• 

drainage. Incomplete drainage may cause 
wetting of the building, furniture etc.

Do not place the controller exposed to direct 

• 

sunlight.

The LCD display may get discolored, failing to 
display the data.

Do not wipe the controller operation panel 

• 

with benzine, thinner, chemical dustcloth, etc.

The panel may get discolored or the coating 
peeled off. If it is heavily dirty, soak a cloth in 
water-diluted neutral detergent, squeeze it well 
and wipe the panel clean. And wipe it with an-
other dry cloth.

Dismantling of the unit, treatment of the re-

• 

frigerant, oil and eventual other parts, should 
be done in accordance with the relevant local 
and national regulations. 

Do not dry the fi lter by exposing it to direct 

 

sunlight or warming it using fi re, etc.  Doing 
so can result in the deformation of the fi lter.

OPERATION RANGE

3. 

If the temperature or the humidity is beyond the 
following conditions, safety devices may work and 
the air conditioner may not operate, or sometimes, 
water may drop from the indoor unit.

OPERATION

TEMPERATURE (°F)

OUTDOOR

INDOOR

COOLING

23 to 115 (DB)

57 to 77 (WB)

HEATING

0 to 60 (WB)

59 to 80.5 (DB)

DB: Dry bulb temperature
WB: Wet bulb temperature

The setting temperature range of the remote con-
troller is 60°F to 90°F.

INSTALLATION SITE

4. 

Regarding places for installation

Is the air conditioner installed at a well-venti-

• 

lated place where there are no obstacles 
around?

Do not use the air conditioner in the follow-

• 

ing places.

a.  Filled with much mineral oil such as cutting oil

b.  Where there is much salt such as a beach 

area

c.  Where sulfured gas exists such as a hot-

spring resort

d.  Where there are considerable voltage fl uctua-

tions such as a factory or plant

e.  Vehicles and vessels
 f .   Where there is much spray of oil and vapor 

such as a cookery, etc.

g.  Where there are machines generating electro-

magnetic waves

h.  Filled with acid and/or alkaline steam or vapor

Is a snow protection measure taken?

• 

For details, consult your dealer.

Regarding wiring

All wiring must be performed by an autho-

• 

rized electrician.

To do wiring, ask your dealer. Never do it by 
yourself.

Make sure that a separate power supply cir-

• 

cuit is provided for this air conditioner and 
that all electrical work is carried out by quali-
fi ed personnel according to local laws and 
regulations.

Pay attention to running noises, too

Are the following places selected?

• 

a.  A place that can suffi ciently withstand the 

weight of the air conditioner with less running 
noises and vibrations.

b.  A place where the hot wind discharged from 

the air outlet of the outdoor unit and the run-
ning noises.

Are you sure that there are no obstacles near 

• 

the air outlet of the outdoor unit?

Such obstacles may result in declined perfor-
mance and increased running noises.

If abnormal noises occur in use, stop the 

• 

operation of the air conditioner, consult your 
dealer.

Regarding drainage of drain piping

Is the drain piping executed to perform com-

• 

plete drainage?

If proper drainage is not carried out from the 
outdoor drain pipes during air-conditioning op-
eration, chances are that dust and dirt are 
clogged in the pipe. This may result in a water 
leakage from the indoor unit. Under such circum-
stances, stop the operation of the air conditioner, 
and then consult your dealer or our service sta-
tion.

01_EN_3PN07520-2A.indd   4

01_EN_3PN07520-2A.indd   4

12/24/2008   2:47:01 PM

12/24/2008   2:47:01 PM

Summary of Contents for SkyAir FAQ18PVJU

Page 1: ...nce This manual should be left with the equipment owner Lire soigneusement ces instructions avant l installation Conserver ce manuel port e de main pour r f rence ult rieure Ce manuel doit tre donn au...

Page 2: ...1 2 9 10 3 1 4 5 6 7 13 14 15 16 17 18 19 20 21 11 8 12 1 b d f k e i h a j d f g e c 3 2 4...

Page 3: ...ntrollers control one indoor unit The unit is individually operated NOTE Contact your dealer in case of two remote con trollers control system Names and functions of parts Refer to figure 2 on page 1...

Page 4: ...sufficiently to avoid this hazard Safely dispose of the packing materials Packing materials such as nails and other metal or wooden parts may cause stabs or other inju ries Tear apart and throw away p...

Page 5: ...above 80 or if the drain outlet gets blocked Avoid placing the controller in a spot splashed with water Water coming inside the unit may cause an elec tric leak or may damage the internal electronic...

Page 6: ...is much salt such as a beach area c Where sulfured gas exists such as a hot spring resort d Where there are considerable voltage fluctua tions such as a factory or plant e Vehicles and vessels f Where...

Page 7: ...AIR FLOW DIRECTION ADJUST 10 DISPLAY TIME TO CLEAN AIR FIL TER Refer to HOW TO CLEAN THE AIR FILTER 11 DISPLAY DEFROST Refer to DEFROST OPERATION 12 NON FUNCTIONING DISPLAY If that particular function...

Page 8: ...irection to the right and left Air outlet 10 AIR FLOW DIRECTION ADJUST There are 2 ways of adjusting the air discharge angle A Up and down direction B Left and right direction A UP AND DOWN DIRECTION...

Page 9: ...is swinging COOLING HEATING AUTOMATIC FAN AND PROGRAM DRY OPERATION Operate in the following order 1 OPERATION MODE SELECTOR Press OPERATION MODE SELECTOR button several times and select the OPERATIO...

Page 10: ...n operation NOTE The setting temperature range of the remote controller is 60 F to 90 F FAN SPEED CONTROL Press FAN SPEED CONTROL button High or Low fan speed can be selected The microchip may sometim...

Page 11: ...me watts of elec tricity is being used even if the system is not operating Turn off the main power supply switch for saving energy When reoperating turn on the main power supply switch 6 hours before...

Page 12: ...ine thinner or other volatile substances polishing powder or hard scrub brushes to clean the pan el Make sure the front panel is solidly in place Open the front panel 1 Place your fingers on the protr...

Page 13: ...The system does not start when the display shows and it flashes for few seconds after pressing an operation button This is because the system is under central ized control Flashes on the display indic...

Page 14: ...the air conditioner is in abnormal con ditions smell of something burning etc unplug the power cord from the outlet and contact your dealer Continued operation under such circumstances may result in a...

Page 15: ...lated If the air filter is clogged Ask a qualified service person to clean the air filters Refer to MAINTENANCE If the set temperature is not proper Refer to ADJUSTMENT If the FAN SPEED button is set...

Page 16: ...3PN07520 2A EM08A090 0902 HT...

Reviews: