background image

2 User safety instructions

Operation manual

3

35A5V1B
R32 Split series
3P717028-1 – 2022.11

concerning use of the appliance in a
safe way and understand the hazards
involved.

Children SHALL NOT play with the
appliance.

Cleaning and user maintenance
SHALL NOT be made by children
without supervision.

WARNING

To prevent electrical shocks or fire:

▪ Do NOT rinse the unit.

▪ Do NOT operate the unit with wet

hands.

▪ Do NOT place any objects containing

water on the unit.

CAUTION

▪ Do NOT place any objects or

equipment on top of the unit.

▪ Do NOT sit, climb or stand on the

unit.

▪ Units are marked with the following symbol:

This  means  that  electrical  and  electronic  products  may  NOT  be
mixed  with  unsorted  household  waste.  Do  NOT  try  to  dismantle
the  system  yourself:  dismantling  the  system,  treatment  of  the
refrigerant,  of  oil  and  of  other  parts  MUST  be  done  by  an
authorised installer and MUST comply with applicable legislation.

Units MUST be treated at a specialised treatment facility for reuse,
recycling  and  recovery.  By  ensuring  this  product  is  disposed  of
correctly, you will help to prevent potential negative consequences
for  the  environment  and  human  health.  For  more  information,
contact your installer or local authority.

▪ Batteries are marked with the following symbol:

This  means  that  the  batteries  may  NOT  be  mixed  with  unsorted
household  waste.  If  a  chemical  symbol  is  printed  beneath  the
symbol,  this  chemical  symbol  means  that  the  battery  contains  a
heavy metal above a certain concentration.

Possible chemical symbols are: Pb: lead (>0.004%).

Waste  batteries  MUST  be  treated  at  a  specialised  treatment
facility  for  reuse.  By  ensuring  waste  batteries  are  disposed  of
correctly, you will help to prevent potential negative consequences
for the environment and human health.

2.2

Instructions for safe operation

WARNING: MILDLY FLAMMABLE
MATERIAL

The refrigerant inside this unit is mildly
flammable.

CAUTION

Do NOT insert fingers, rods or other
objects into the air inlet or outlet. When
the fan is rotating at high speed, it will
cause injury.

WARNING

▪ Do NOT modify, disassemble,

remove, reinstall or repair the unit
yourself as incorrect dismantling or
installation may cause an electrical
shock or fire. Contact your dealer.

▪ In case of accidental refrigerant

leaks, make sure there are no naked
flames. The refrigerant itself is
entirely safe, non-toxic and mildly
flammable, but it will generate toxic
gas when it accidentally leaks into a
room where combustible air from fan
heaters, gas cookers, etc. is present.
Always have qualified service
personnel confirm that the point of
leakage has been repaired or
corrected before resuming operation.

CAUTION

ALWAYS use the wireless remote
control or other user interface (if
applicable) to adjust the position of the
flaps and louvers. When the flaps and
louvers are swinging and you move
them forcibly by hand, the mechanism
will break.

CAUTION

NEVER expose little children, plants or
animals directly to the airflow.

WARNING

Do NOT place a flammable spray
bottle near the air conditioner and do
NOT use sprays near the unit. Doing
so may result in a fire.

Summary of Contents for Siesta ATXD25A5V1B

Page 1: ...Operation manual R32 Split series English Operation manual R32 Split series ATXD25A5V1B ATXD35A5V1B...

Page 2: ...14 8 1 2 Symptom A blowing sound is heard 14 8 1 3 Symptom A ticking sound is heard 14 8 1 4 Symptom A whistling sound is heard 14 8 1 5 Symptom A clicking sound during operation or idle time is hear...

Page 3: ...contains a heavy metal above a certain concentration Possible chemical symbols are Pb lead 0 004 Waste batteries MUST be treated at a specialised treatment facility for reuse By ensuring waste batter...

Page 4: ...ames an operating gas appliance or an operating electric heater The room size shall be as specified in the General safety precaution DANGER RISK OF ELECTROCUTION To clean the air conditioner or air fi...

Page 5: ...ic Temperature setting 25 C Airflow rate Automatic 3 2 About the user interface Wireless remote control INFORMATION The indoor unit is delivered with the wireless remote control as the user interface...

Page 6: ...g beep Operation stops 4 Before operation 4 1 To mount the wireless remote control holder c b a 2 a Wireless remote control b Screws field supply c Wireless remote control holder 1 Choose a place wher...

Page 7: ...the temperature setpoint Cooling The system cools down a room to the temperature setpoint Fan The system only controls the airflow airflow rate and airflow direction The system does NOT control the t...

Page 8: ...omatically sets the fixed airflow position upward in Cooling and downward in Heating operation mode Cooling operation mode Heating operation mode INFORMATION Powerful and Comfort airflow operation CAN...

Page 9: ...ure setting 0 5 C up in cooling 2 0 C down in heating to prevent excessive cooling heating and ensure a comfortable sleeping temperature Use this feature if the unit is operating and you want to stop...

Page 10: ...ss LAN is is off blinks in 0 5 second interval running and ready to connect to the home network via WPS button on the router is off blinks in 1 second interval connected to the home network via SSID K...

Page 11: ...when using a room fumigation type insecticide Chemicals could collect in the unit and endanger the health of people who are hypersensitive to chemicals 7 Maintenance and service 7 1 Overview Maintena...

Page 12: ...ssible consequence Discoloration and deformation Do NOT use water or air of 40 C or higher Possible consequence Discoloration and deformation Do NOT use polishing compounds Do NOT use a scrubbing brus...

Page 13: ...anel at both sides and at the center until it clicks 7 8 To take following items into account before a long idle period 1 Set the mode to fan only by pressing button to dry the inside of the unit 2 Af...

Page 14: ...inside a room becomes uneven It is necessary to clean the interior of the indoor unit Ask your dealer for details on cleaning the unit This operation requires a qualified service person When the air c...

Page 15: ...voltage current sensor abnormality Outdoor temperature thermistor abnormality Discharge pipe thermistor abnormality Outdoor heat exchanger thermistor abnormality Electrical parts heat error Radiation...

Page 16: ...TANBUL T RK YE Tel 0216 453 27 00 Faks 0216 671 06 00 a r Merkezi 444 999 0 Web www daikin com tr G lsuyu Mahallesi Fevzi akmak Caddesi Bur ak Sokak No 20 34848 Maltepe 3P717028 1 2022 11 Copyright 20...

Reviews: