background image

4 Before operation

Operation manual

6

35A5V1B

R32 Split series

3P717028-1 – 2022.11

Icon

Description

Operation mode = Cooling

Operation mode = Fan only

Powerful operation is active

Econo operation is active

The indoor unit receives a signal from the wireless
remote control

Current temperature setting

Airflow rate = Automatic

Airflow rate = Indoor unit quiet

Airflow rate = High

Airflow rate = Medium high

Airflow rate = Medium

Airflow rate = Medium low

Airflow rate = Low

Comfort operation is active

Automatic vertical swing is active

Automatic horizontal swing is active

ON timer is active

OFF timer is active

3.2.3

To operate the wireless remote control

a

a

Infrared signal receiver

1

Aim the signal transmitter at the infrared signal receiver on the
indoor unit (maximum distance for communication is 7 m).

Result: 

When  the  indoor  unit  receives  a  signal  from  the  wireless

remote control, you will hear a sound:

Sound

Description

Beep-beep

Operation starts.

Beep

Setting changes.

Long beep

Operation stops.

4

Before operation

4.1

To mount the wireless remote
control holder

c

b

a

a

Wireless remote control

b

Screws (field supply)

c

Wireless remote control holder

1

Choose a place where the signals reach the unit.

2

Attach the holder with screws to the wall or a similar location.

3

Hang the wireless remote control on the holder.

4.2

To insert the batteries

The batteries will last for about 1 year.

1

Remove the back cover.

2

Insert both batteries at once.

3

Put the cover back.

2

3

1

AAA.LR03

4.3

To turn on the power supply

1

Turn the circuit breaker on.

Result: 

The  flap  of  the  indoor  unit  will  open  and  close  to  set  the

reference position.

5

Operation

5.1

Operation range

Use the system in the following temperature and humidity ranges for
safe and effective operation.

Operation mode

Operation range

Cooling

(a)(b)

▪ Outdoor temperature: –10~50°C DB

▪ Indoor temperature: 18~32°C DB

▪ Indoor humidity: ≤80%

Heating

(a)

▪ Outdoor temperature: –20~24°C DB

▪ Indoor temperature: 10~30°C DB

Drying

(a)

▪ Outdoor temperature: –10~50°C DB

▪ Indoor temperature: 18~32°C DB

▪ Indoor humidity: ≤80%

(a)

A safety device might stop the operation of the system if the unit
runs outside its operation range.

Summary of Contents for Siesta ATXD25A5V1B

Page 1: ...Operation manual R32 Split series English Operation manual R32 Split series ATXD25A5V1B ATXD35A5V1B...

Page 2: ...14 8 1 2 Symptom A blowing sound is heard 14 8 1 3 Symptom A ticking sound is heard 14 8 1 4 Symptom A whistling sound is heard 14 8 1 5 Symptom A clicking sound during operation or idle time is hear...

Page 3: ...contains a heavy metal above a certain concentration Possible chemical symbols are Pb lead 0 004 Waste batteries MUST be treated at a specialised treatment facility for reuse By ensuring waste batter...

Page 4: ...ames an operating gas appliance or an operating electric heater The room size shall be as specified in the General safety precaution DANGER RISK OF ELECTROCUTION To clean the air conditioner or air fi...

Page 5: ...ic Temperature setting 25 C Airflow rate Automatic 3 2 About the user interface Wireless remote control INFORMATION The indoor unit is delivered with the wireless remote control as the user interface...

Page 6: ...g beep Operation stops 4 Before operation 4 1 To mount the wireless remote control holder c b a 2 a Wireless remote control b Screws field supply c Wireless remote control holder 1 Choose a place wher...

Page 7: ...the temperature setpoint Cooling The system cools down a room to the temperature setpoint Fan The system only controls the airflow airflow rate and airflow direction The system does NOT control the t...

Page 8: ...omatically sets the fixed airflow position upward in Cooling and downward in Heating operation mode Cooling operation mode Heating operation mode INFORMATION Powerful and Comfort airflow operation CAN...

Page 9: ...ure setting 0 5 C up in cooling 2 0 C down in heating to prevent excessive cooling heating and ensure a comfortable sleeping temperature Use this feature if the unit is operating and you want to stop...

Page 10: ...ss LAN is is off blinks in 0 5 second interval running and ready to connect to the home network via WPS button on the router is off blinks in 1 second interval connected to the home network via SSID K...

Page 11: ...when using a room fumigation type insecticide Chemicals could collect in the unit and endanger the health of people who are hypersensitive to chemicals 7 Maintenance and service 7 1 Overview Maintena...

Page 12: ...ssible consequence Discoloration and deformation Do NOT use water or air of 40 C or higher Possible consequence Discoloration and deformation Do NOT use polishing compounds Do NOT use a scrubbing brus...

Page 13: ...anel at both sides and at the center until it clicks 7 8 To take following items into account before a long idle period 1 Set the mode to fan only by pressing button to dry the inside of the unit 2 Af...

Page 14: ...inside a room becomes uneven It is necessary to clean the interior of the indoor unit Ask your dealer for details on cleaning the unit This operation requires a qualified service person When the air c...

Page 15: ...voltage current sensor abnormality Outdoor temperature thermistor abnormality Discharge pipe thermistor abnormality Outdoor heat exchanger thermistor abnormality Electrical parts heat error Radiation...

Page 16: ...TANBUL T RK YE Tel 0216 453 27 00 Faks 0216 671 06 00 a r Merkezi 444 999 0 Web www daikin com tr G lsuyu Mahallesi Fevzi akmak Caddesi Bur ak Sokak No 20 34848 Maltepe 3P717028 1 2022 11 Copyright 20...

Reviews: