background image

6 Energy saving and optimum operation

Operation manual

11

35A5V1B
R32 Split series
3P717028-1 – 2022.11

2

Change  to  the  SP  menu    by  pressing 

  twice  or 

repeatedly.

(5 sec.) 

3

Hold 

 for at least 2 seconds to confirm the selection.

Result: 

 is blinking. The operation and timer LEDs are blinking

at  the  same  time  in  1  s  interval.  The  setting  is  reset  to  the
factory default.

4

Press 

 to exit the menu.

Result: 

The display will return to the default screen.

To turn off the wireless LAN connection

If you want to turn off the wireless connection function:

1

On  home  screen  menu,  press 

  for  at  least  5  seconds

while the unit is not operating.

Result: 

The SP menu   appears.   is blinking.

2

Change  to  the  SP  menu 

  by  pressing 

  once  or 

repeatedly.

(5 sec.) 

OFF

3

Hold 

 for at least 2 seconds to confirm the selection.

Result: 

  is  blinking.  The  operation  and  timer  LEDs  are

blinking alternately in 1 s interval. Communication is OFF.

4

Press 

 to exit the menu.

Result: 

The display will return to the default screen.

6

Energy saving and optimum
operation

INFORMATION

▪ Even if the unit is turned OFF, it consumes electricity.

▪ When the power turns back on after a power break, the

previously selected mode will be resumed.

CAUTION

NEVER  expose  little  children,  plants  or  animals  directly  to
the airflow.

NOTICE

Do NOT place objects below the indoor and/or outdoor unit
that  may  get  wet.  Otherwise  condensation  on  the  unit  or
refrigerant pipes, air filter dirt or drain blockage may cause
dripping,  and  objects  under  the  unit  may  get  dirty  or
damaged.

WARNING

Do  NOT  place  a  flammable  spray  bottle  near  the  air
conditioner and do NOT use sprays near the unit. Doing so
may result in a fire.

CAUTION

Do  NOT  operate  the  system  when  using  a  room
fumigation-type  insecticide.  Chemicals  could  collect  in  the
unit,  and  endanger  the  health  of  people  who  are
hypersensitive to chemicals.

7

Maintenance and service

7.1

Overview: Maintenance and
service

The installer has to perform a yearly maintenance.

About the refrigerant

This  product  contains  fluorinated  greenhouse  gases.  Do  NOT  vent
gases into the atmosphere.

Refrigerant type: R32

Global warming potential (GWP) value: 675

NOTICE

Applicable  legislation  on 

fluorinated  greenhouse  gases

requires  that  the  refrigerant  charge  of  the  unit  is  indicated
both in weight and CO

2

 equivalent.

Formula  to  calculate  the  quantity  in  CO

2

  equivalent

tonnes:

  GWP  value  of  the  refrigerant  ×  total  refrigerant

charge [in kg]/1000

Contact your installer for more information.

NOTICE

Maintenance  MUST  be  done  by  an  authorised  installer  or
service agent.

We  recommend  performing  maintenance  at  least  once  a
year. However, applicable legislation might require shorter
maintenance intervals.

WARNING

▪ The  refrigerant  inside  the  unit  is  mildly  flammable,  but

normally  does  NOT  leak.  If  the  refrigerant  leaks  in  the
room  and  comes  in  contact  with  fire  from  a  burner,  a
heater,  or  a  cooker,  this  may  result  in  fire,  or  the
formation of a harmful gas.

▪ Turn  OFF  any  combustible  heating  devices,  ventilate

the room, and contact the dealer where you purchased
the unit.

▪ Do  NOT  use  the  unit  until  a  service  person  confirms

that the part from which the refrigerant leaked has been
repaired.

WARNING

▪ Do NOT pierce or burn refrigerant cycle parts.

▪ Do NOT use cleaning materials or means to accelerate

the  defrosting  process  other  than  those  recommended
by the manufacturer.

▪ Be  aware  that  the  refrigerant  inside  the  system  is

odourless.

WARNING

The  appliance  shall  be  stored  in  a  room  without
continuously  operating  ignition  sources  (example:  open
flames, an operating gas appliance or an operating electric
heater).

Summary of Contents for Siesta ATXD25A5V1B

Page 1: ...Operation manual R32 Split series English Operation manual R32 Split series ATXD25A5V1B ATXD35A5V1B...

Page 2: ...14 8 1 2 Symptom A blowing sound is heard 14 8 1 3 Symptom A ticking sound is heard 14 8 1 4 Symptom A whistling sound is heard 14 8 1 5 Symptom A clicking sound during operation or idle time is hear...

Page 3: ...contains a heavy metal above a certain concentration Possible chemical symbols are Pb lead 0 004 Waste batteries MUST be treated at a specialised treatment facility for reuse By ensuring waste batter...

Page 4: ...ames an operating gas appliance or an operating electric heater The room size shall be as specified in the General safety precaution DANGER RISK OF ELECTROCUTION To clean the air conditioner or air fi...

Page 5: ...ic Temperature setting 25 C Airflow rate Automatic 3 2 About the user interface Wireless remote control INFORMATION The indoor unit is delivered with the wireless remote control as the user interface...

Page 6: ...g beep Operation stops 4 Before operation 4 1 To mount the wireless remote control holder c b a 2 a Wireless remote control b Screws field supply c Wireless remote control holder 1 Choose a place wher...

Page 7: ...the temperature setpoint Cooling The system cools down a room to the temperature setpoint Fan The system only controls the airflow airflow rate and airflow direction The system does NOT control the t...

Page 8: ...omatically sets the fixed airflow position upward in Cooling and downward in Heating operation mode Cooling operation mode Heating operation mode INFORMATION Powerful and Comfort airflow operation CAN...

Page 9: ...ure setting 0 5 C up in cooling 2 0 C down in heating to prevent excessive cooling heating and ensure a comfortable sleeping temperature Use this feature if the unit is operating and you want to stop...

Page 10: ...ss LAN is is off blinks in 0 5 second interval running and ready to connect to the home network via WPS button on the router is off blinks in 1 second interval connected to the home network via SSID K...

Page 11: ...when using a room fumigation type insecticide Chemicals could collect in the unit and endanger the health of people who are hypersensitive to chemicals 7 Maintenance and service 7 1 Overview Maintena...

Page 12: ...ssible consequence Discoloration and deformation Do NOT use water or air of 40 C or higher Possible consequence Discoloration and deformation Do NOT use polishing compounds Do NOT use a scrubbing brus...

Page 13: ...anel at both sides and at the center until it clicks 7 8 To take following items into account before a long idle period 1 Set the mode to fan only by pressing button to dry the inside of the unit 2 Af...

Page 14: ...inside a room becomes uneven It is necessary to clean the interior of the indoor unit Ask your dealer for details on cleaning the unit This operation requires a qualified service person When the air c...

Page 15: ...voltage current sensor abnormality Outdoor temperature thermistor abnormality Discharge pipe thermistor abnormality Outdoor heat exchanger thermistor abnormality Electrical parts heat error Radiation...

Page 16: ...TANBUL T RK YE Tel 0216 453 27 00 Faks 0216 671 06 00 a r Merkezi 444 999 0 Web www daikin com tr G lsuyu Mahallesi Fevzi akmak Caddesi Bur ak Sokak No 20 34848 Maltepe 3P717028 1 2022 11 Copyright 20...

Reviews: