background image

8 Troubleshooting

Operation manual

13

35A5V1B
R32 Split series
3P717028-1 – 2022.11

INFORMATION

▪ If  the  dust  does  NOT  come  off  easily,  wash  the  air

filters  with  a  neutral  detergent  diluted  in  lukewarm
water. Dry the air filters in the shade.

▪ Be sure to remove the titanium apatite deodorising and

silver particle filters.

▪ It  is  recommended  to  clean  the  air  filters  every  2

weeks.

7.5

To clean the titanium apatite
deodorising filter and the silver
particle filter (Ag-ion filter)

INFORMATION

Clean the filter with water every 6 months.

1

Remove  the  titanium  apatite  deodorising  and  silver  particle
filters from the tabs.

a

Tabs

2

Remove the dust from the filter with a vacuum cleaner.

3

Soak  the  filter  for  10  to  15  minutes  in  warm  water.  Do  NOT
remove the filter from the frame.

4

After washing, shake off remaining water and dry the filter in the
shade. Do NOT wring out the filter when removing water.

7.6

To replace the titanium apatite
deodorising filter and the silver
particle filter (Ag-ion filter)

INFORMATION

Replace the filter every 3 years.

1

Remove  the  filter  from  the  tabs  of  the  filter  frame  and  replace
the filter with a new one.

INFORMATION

▪ Do NOT throw away the filter frame, but use it again.

▪ Dispose of the old filter as non-flammable waste.

7.7

To close the front panel

1

Set the filters as they were.

2

Gently press the front panel at both sides and at the center until
it clicks.

7.8

To take following items into
account before a long idle period

1

Set the mode to 

fan only

 by pressing 

 button to dry the

inside of the unit.

2

After operation stops, turn the breaker OFF.

3

Clean the air filters and replace them in their original positions.

4

Remove the batteries from the wireless remote control.

INFORMATION

It  is  recommended  to  have  periodical  maintenance
performed  by  a  specialist.  For  specialist  maintenance,
contact  your  dealer.  Maintenance  costs  shall  be  borne  by
the customer.

In  certain  operating  conditions  the  inside  of  the  unit  may
get dirty after several seasons of use. This results in poor
performance.

8

Troubleshooting

If one of the following malfunctions occur, take the measures shown
below and contact your dealer.

WARNING

Stop  operation  and  shut  OFF  the  power  if  anything
unusual occurs (burning smells etc.).

Leaving  the  unit  running  under  such  circumstances  may
cause  breakage,  electrical  shock  or  fire.  Contact  your
dealer.

The system MUST be repaired by a qualified service person.

Malfunction

Measure

If a safety device such as a fuse, a
breaker or an earth leakage breaker
frequently actuates or the ON/OFF
switch does NOT properly work.

Turn OFF the main power
switch.

If water leaks from the unit.

Stop the operation.

The operation switch does NOT work
well.

Turn OFF the power
supply.

If the user interface display indicates the
unit number, the operation lamp flashes
and the malfunction code appears.

Notify your installer and
report the malfunction
code.

Summary of Contents for Siesta ATXD25A5V1B

Page 1: ...Operation manual R32 Split series English Operation manual R32 Split series ATXD25A5V1B ATXD35A5V1B...

Page 2: ...14 8 1 2 Symptom A blowing sound is heard 14 8 1 3 Symptom A ticking sound is heard 14 8 1 4 Symptom A whistling sound is heard 14 8 1 5 Symptom A clicking sound during operation or idle time is hear...

Page 3: ...contains a heavy metal above a certain concentration Possible chemical symbols are Pb lead 0 004 Waste batteries MUST be treated at a specialised treatment facility for reuse By ensuring waste batter...

Page 4: ...ames an operating gas appliance or an operating electric heater The room size shall be as specified in the General safety precaution DANGER RISK OF ELECTROCUTION To clean the air conditioner or air fi...

Page 5: ...ic Temperature setting 25 C Airflow rate Automatic 3 2 About the user interface Wireless remote control INFORMATION The indoor unit is delivered with the wireless remote control as the user interface...

Page 6: ...g beep Operation stops 4 Before operation 4 1 To mount the wireless remote control holder c b a 2 a Wireless remote control b Screws field supply c Wireless remote control holder 1 Choose a place wher...

Page 7: ...the temperature setpoint Cooling The system cools down a room to the temperature setpoint Fan The system only controls the airflow airflow rate and airflow direction The system does NOT control the t...

Page 8: ...omatically sets the fixed airflow position upward in Cooling and downward in Heating operation mode Cooling operation mode Heating operation mode INFORMATION Powerful and Comfort airflow operation CAN...

Page 9: ...ure setting 0 5 C up in cooling 2 0 C down in heating to prevent excessive cooling heating and ensure a comfortable sleeping temperature Use this feature if the unit is operating and you want to stop...

Page 10: ...ss LAN is is off blinks in 0 5 second interval running and ready to connect to the home network via WPS button on the router is off blinks in 1 second interval connected to the home network via SSID K...

Page 11: ...when using a room fumigation type insecticide Chemicals could collect in the unit and endanger the health of people who are hypersensitive to chemicals 7 Maintenance and service 7 1 Overview Maintena...

Page 12: ...ssible consequence Discoloration and deformation Do NOT use water or air of 40 C or higher Possible consequence Discoloration and deformation Do NOT use polishing compounds Do NOT use a scrubbing brus...

Page 13: ...anel at both sides and at the center until it clicks 7 8 To take following items into account before a long idle period 1 Set the mode to fan only by pressing button to dry the inside of the unit 2 Af...

Page 14: ...inside a room becomes uneven It is necessary to clean the interior of the indoor unit Ask your dealer for details on cleaning the unit This operation requires a qualified service person When the air c...

Page 15: ...voltage current sensor abnormality Outdoor temperature thermistor abnormality Discharge pipe thermistor abnormality Outdoor heat exchanger thermistor abnormality Electrical parts heat error Radiation...

Page 16: ...TANBUL T RK YE Tel 0216 453 27 00 Faks 0216 671 06 00 a r Merkezi 444 999 0 Web www daikin com tr G lsuyu Mahallesi Fevzi akmak Caddesi Bur ak Sokak No 20 34848 Maltepe 3P717028 1 2022 11 Copyright 20...