9 Disposal

Operation manual

15

35A5V1B
R32 Split series
3P717028-1 – 2022.11

Outdoor unit

Error code

Description

4-way valve abnormality

Outdoor unit PCB abnormality

Overload activation (compressor overload)

Compressor lock

DC fan lock

Input power overcurrent

Discharge pipe temperature control

High-pressure control (in cooling mode)

Compressor system sensor abnormality

Position sensor abnormality

DC voltage / current sensor abnormality

Outdoor temperature thermistor abnormality

Discharge pipe thermistor abnormality

Outdoor heat exchanger thermistor abnormality

Electrical parts heat error

Radiation fin temperature rise

Inverter instantaneous overcurrent (DC)

Radiation fin thermistor abnormality

Compressor internal temperature error

9

Disposal

NOTICE

Do  NOT  try  to  dismantle  the  system  yourself:  dismantling
of  the  system,  treatment  of  the  refrigerant,  oil  and  other
parts  MUST  comply  with  applicable  legislation.  Units
MUST  be  treated  at  a  specialised  treatment  facility  for
reuse, recycling and recovery.

Summary of Contents for Siesta ATXD25A5V1B

Page 1: ...Operation manual R32 Split series English Operation manual R32 Split series ATXD25A5V1B ATXD35A5V1B...

Page 2: ...14 8 1 2 Symptom A blowing sound is heard 14 8 1 3 Symptom A ticking sound is heard 14 8 1 4 Symptom A whistling sound is heard 14 8 1 5 Symptom A clicking sound during operation or idle time is hear...

Page 3: ...contains a heavy metal above a certain concentration Possible chemical symbols are Pb lead 0 004 Waste batteries MUST be treated at a specialised treatment facility for reuse By ensuring waste batter...

Page 4: ...ames an operating gas appliance or an operating electric heater The room size shall be as specified in the General safety precaution DANGER RISK OF ELECTROCUTION To clean the air conditioner or air fi...

Page 5: ...ic Temperature setting 25 C Airflow rate Automatic 3 2 About the user interface Wireless remote control INFORMATION The indoor unit is delivered with the wireless remote control as the user interface...

Page 6: ...g beep Operation stops 4 Before operation 4 1 To mount the wireless remote control holder c b a 2 a Wireless remote control b Screws field supply c Wireless remote control holder 1 Choose a place wher...

Page 7: ...the temperature setpoint Cooling The system cools down a room to the temperature setpoint Fan The system only controls the airflow airflow rate and airflow direction The system does NOT control the t...

Page 8: ...omatically sets the fixed airflow position upward in Cooling and downward in Heating operation mode Cooling operation mode Heating operation mode INFORMATION Powerful and Comfort airflow operation CAN...

Page 9: ...ure setting 0 5 C up in cooling 2 0 C down in heating to prevent excessive cooling heating and ensure a comfortable sleeping temperature Use this feature if the unit is operating and you want to stop...

Page 10: ...ss LAN is is off blinks in 0 5 second interval running and ready to connect to the home network via WPS button on the router is off blinks in 1 second interval connected to the home network via SSID K...

Page 11: ...when using a room fumigation type insecticide Chemicals could collect in the unit and endanger the health of people who are hypersensitive to chemicals 7 Maintenance and service 7 1 Overview Maintena...

Page 12: ...ssible consequence Discoloration and deformation Do NOT use water or air of 40 C or higher Possible consequence Discoloration and deformation Do NOT use polishing compounds Do NOT use a scrubbing brus...

Page 13: ...anel at both sides and at the center until it clicks 7 8 To take following items into account before a long idle period 1 Set the mode to fan only by pressing button to dry the inside of the unit 2 Af...

Page 14: ...inside a room becomes uneven It is necessary to clean the interior of the indoor unit Ask your dealer for details on cleaning the unit This operation requires a qualified service person When the air c...

Page 15: ...voltage current sensor abnormality Outdoor temperature thermistor abnormality Discharge pipe thermistor abnormality Outdoor heat exchanger thermistor abnormality Electrical parts heat error Radiation...

Page 16: ...TANBUL T RK YE Tel 0216 453 27 00 Faks 0216 671 06 00 a r Merkezi 444 999 0 Web www daikin com tr G lsuyu Mahallesi Fevzi akmak Caddesi Bur ak Sokak No 20 34848 Maltepe 3P717028 1 2022 11 Copyright 20...

Reviews: