Field Settings
SiBE041213E
107
Tips for Servicing
3. Field Settings
3.1
When 2 Units are Installed in 1 Room
Outline
When 2 indoor units are installed in 1 room, 1 of the 2 indoor units and the corresponding
wireless remote controller can be set for different addresses.
Both the indoor unit PCB and the wireless remote controller need alteration.
Indoor Unit PCB
(1) Remove the front grille.
(2) Remove the electrical box.
(3) Remove the shield plate of the electrical box.
(4) Cut the address setting jumper JA on the PCB.
Caution
Replace the PCB if you accidentally cut a wrong jumper.
Jumpers are necessary for electronic circuit. Improper operation may occur if you cut any of
them.
Wireless Remote
Controller
Cut the address setting jumper.
3.2
Model Type Setting
This remote controller is common to the heat pump model and cooling only model.
The heating operation will not be available when the jumper on the left side is cut. Replace
the remote controller if you cut the jumper on the left side.
ADDRESS
JA
ADDRESS
JA
EXIST
1
CUT
2
(R18414)
(R18416)
ADDRESS
EXIST
1
CUT
2
Jumper
∗
Do not cut the left jumper.
Never cut this jumper.
(R18451)