3.11 Electronic Expansion Valve Control
Outline
The following items are included in the electronic expansion valve control.
Electronic expansion valve is fully closed
1. Electronic expansion valve is fully closed when turning on the power.
2. Pressure equalizing control
Open Control
1. Electronic expansion valve control when starting operation
2. Electronic expansion valve control when the frequency changes
3. Electronic expansion valve control for defrosting
4. Electronic expansion valve control when the discharge pipe temperature is abnormally high
5. Electronic expansion valve control when the discharge pipe thermistor is disconnected
Feedback Control
Target discharge pipe temperature control
Detail
The followings are the examples of electronic expansion valve control which function in each
operation mode.
Cooling
−
h
−
−
−
−
−
−
−
−
h
−
h
−
−
−
−
−
−
h
−
−
−
−
−
−
−
−
−
h
h
−
−
h
h
h
h
h
h
h
h
h
−
−
−
h
−
−
−
−
−
−
−
−
h
−
Heating
−
h
−
−
−
−
−
−
−
−
h
−
h
−
−
−
−
−
−
h
−
−
−
−
−
−
−
−
−
h
h
−
−
h
h
h
h
−
−
−
−
−
−
−
−
−
−
h
h
−
−
−
−
−
−
−
−
h
h
h
h
h
h
−
h
: Available
— : Not available
Starting control
Control when the frequency changes
Target discharge pipe temperature control
Control for disconnection of the discharge
pipe thermistor
High discharge pipe temperature control
Pressure equalizing control
Opening limit control
Starting control
Control when the frequency changes
Target discharge pipe temperature control
Control for disconnection of the discharge
pipe thermistor
High discharge pipe temperature control
Defrost control
Pressure equalizing control
Opening limit control
When the power turns on or when the compressor
stops
When the operation starts
When the frequency changes under starting control
During target discharge pipe temperature control
When the frequency changes under target discharge
pipe temperature control
When the disconnection of the discharge pipe
thermistor is ascertained
When the frequency changes under the control for
disconnection of the discharge pipe thermistor
Under defrost control
Summary of Contents for RXS35K2V1B
Page 12: ...SiBE041213E 1 List of Functions Part 1 List of Functions 1 Functions 2 ...
Page 14: ...SiBE041213E 3 Specifications Part 2 Specifications 1 Specifications 4 ...
Page 59: ...SiBE041213E Remote Controller 48 Part 5 Remote Controller 1 Remote Controller 49 ...
Page 129: ...Revision History Month Year Version Revised contents 05 2013 SiBE041213E First edition ...