Control Specification
SiBE041213E
43
Function and Control
3.10 Defrost Control
Outline
Defrosting is carried out by the cooling cycle (reverse cycle). The defrosting time or outdoor
heat exchanger temperature must be more than a certain value to finish defrosting.
Detail
Conditions for Starting Defrost
The starting conditions are determined with the outdoor temperature and the outdoor heat
exchanger temperature.
The system is in heating operation.
The compressor operates for 6 minutes.
More than
A
minutes of accumulated time pass after the start of the operation, or ending the
previous defrosting.
Conditions for Canceling Defrost
The judgment is made with the outdoor heat exchanger temperature. (
B
°C)
: The same value continues.
35 class
42 class
50 class
A
(minutes)
28
30
44
B
(°C)
4 ~ 18
4 ~ 15
4 ~ 12
C
(Hz)
76
48
55
D
(Hz)
86
70
90
E
(seconds)
50
60
60
F
(seconds)
60
120
120
G
(seconds)
480
530
340
H
(seconds)
60
30
50
J
(pulse)
450
450
450
K
(pulse)
200
350
350
L
(pulse)
300
400
350
M
(pulse)
450
450
450
Frequency
Compressor
Four way valve
Fan
ON
OFF
ON
OFF
ON
OFF
0 Hz
0 Hz
C
Hz
D
Hz
5 sec.
K
pulse
M
pulse
J
pulse
Initial opening
PI control
5 sec.
H
sec.
(R18152)
Electronic expansion
valve opening
E
sec.
F
sec.
G
sec.
L
pulse
Summary of Contents for RXS35K2V1B
Page 12: ...SiBE041213E 1 List of Functions Part 1 List of Functions 1 Functions 2 ...
Page 14: ...SiBE041213E 3 Specifications Part 2 Specifications 1 Specifications 4 ...
Page 59: ...SiBE041213E Remote Controller 48 Part 5 Remote Controller 1 Remote Controller 49 ...
Page 129: ...Revision History Month Year Version Revised contents 05 2013 SiBE041213E First edition ...