Outdoor Unit
SiBE041213E
9
Printed Circuit Board Connector Wiring Diagram
2. Outdoor Unit
2.1
RXS35K2V1B
Main PCB
Caution
Replace the PCB if you accidentally cut the jumpers other than J4 and J5.
Jumpers are necessary for electronic circuit. Improper operation may occur if you cut any of
them.
1) S10
Connector for filter PCB
2) S20
Connector for electronic expansion valve coil
3) S40
Connector for overload protector
4) S50
Connector for magnetic relay
5) S70
Connector for fan motor
6) S80
Connector for four way valve coil
7) S90
Connector for thermistors
(outdoor temperature, outdoor heat exchanger, discharge pipe)
8) S100
Connector for forced operation button PCB
9) HL3, HN3
Connector for filter PCB
10)HR2
Connector for reactor
11)U, V, W
Connector for compressor
12)FU2
Fuse (3.15 A, 250 V)
13)LED A
LED for service monitor (green)
14)V1
Varistor
15)J4
Jumper for facility setting
∗
Refer to page 108 for detail.
16)J5
Jumper for improvement of defrost performance
∗
Refer to page 110 for detail.
S10
J5
J4
S90
FU2
S100 S50
S70
S40
S20
S80
HL3
HN3
V1
LED A
U VW
HR2
2P254206-11
Summary of Contents for RXS35K2V1B
Page 12: ...SiBE041213E 1 List of Functions Part 1 List of Functions 1 Functions 2 ...
Page 14: ...SiBE041213E 3 Specifications Part 2 Specifications 1 Specifications 4 ...
Page 59: ...SiBE041213E Remote Controller 48 Part 5 Remote Controller 1 Remote Controller 49 ...
Page 129: ...Revision History Month Year Version Revised contents 05 2013 SiBE041213E First edition ...