![Daikin MKS-T Series Service Manual Download Page 117](http://html1.mh-extra.com/html/daikin/mks-t-series/mks-t-series_service-manual_3280982117.webp)
SiSG121917E
Service Diagnosis
Part 6 Service Diagnosis
112
Note
5. Press
TEMP
or
TEMP
button and change the number until you hear the long beep.
6. Diagnose by the sound.
Beep: The left-side number does not correspond with the error code.
Two consecutive beeps: The left-side number corresponds with the error code but the
right-side number does not.
Long beep: Both the left-side and right-side numbers correspond with the error code.
7. Determine the error code.
The numbers indicated when you hear the long beep are the error code.
Refer to Error codes and description on page 114, 115.
8. Press
MODE
button to exit from the diagnosis mode.
The display
T
means the trial operation mode.
Refer to page 187 for trial operation.
9. Press
ON/OFF
button twice to return to the normal mode.
When the remote controller is left untouched for 60 seconds, it returns to the normal mode.
(R19115)
(R19116)
(R14969)
(R19117)