![Daikin MKS-T Series Service Manual Download Page 26](http://html1.mh-extra.com/html/daikin/mks-t-series/mks-t-series_service-manual_3280982026.webp)
Indoor Unit
SiSG121917E
21
Part 2 Specifications
50 Hz, 230 V
Notes:
1. SL: The Quiet fan level of the airflow rate setting.
Model
FDKS50CVMB
FDKS60CVMB
Rated Capacity
5.0 kW Class
6.0 kW Class
Airflow Rates
H
m³/min
(cfm)
12.0 (424)
16.0 (565)
M
11.0 (388)
14.8 (523)
L
10.0 (353)
13.5 (477)
SL
8.4 (297)
11.2 (395)
Fan
Type
Sirocco Fan
Sirocco Fan
Motor Output
W
130
130
Speed
Steps
5 Steps, Quiet, Auto
5 Steps, Quiet, Auto
Air Filter
Removable, Washable, Mildew Proof
Removable, Washable, Mildew Proof
Running Current (Rated)
A
0.64
0.74
Power Consumption (Rated)
W
140
160
Power Factor (Rated)
%
95.1
94.0
Temperature Control
Microcomputer Control
Microcomputer Control
Dimensions (H × W × D)
mm
200 × 900 × 620
200 × 1,100 × 620
Packaged Dimensions (H × W × D)
mm
266 × 1,106 × 751
266 × 1,306 × 751
Weight (Mass)
kg
27
30
Gross Weight (Gross Mass)
kg
34
37
Sound
Pressure
Level
H / M / L / SL
dB(A)
37 / 35 / 33 / 31
38 / 36 / 34 / 32
External Static Pressure
Pa
40
40
Heat Insulation
Both Liquid and Gas Pipes
Both Liquid and Gas Pipes
Piping
Connection
Liquid
mm
φ
6.4
φ
6.4
Gas
mm
φ
12.7
φ
12.7
Drain
mm
VP20 (O.D.
φ
26 / I.D.
φ
20)
VP20 (O.D.
φ
26 / I.D.
φ
20)
Drawing No.
C: 3D060040
C: 3D065479
Conversion Formulae
kcal/h = kW × 860
Btu/h = kW × 3412
cfm = m³/min × 35.3